English
Language : 

5962-89637 Datasheet, PDF (8/10 Pages) List of Unclassifed Manufacturers – MICROCIRCUIT, LINEAR, WIDEBAND RMS-TO-DC CONVERTER, MONOLITHIC SILICON
TABLE II. Electrical test requirements.
MIL-STD-883 test requirements
Interim electrical parameters
(method 5004)
Final electrical test parameters
(method 5004)
Group A test requirements
(method 5005)
Groups C and D end-point
electrical parameters
(method 5005)
Subgroups
(in accordance with
MIL-STD-883, method 5005,
table I)
1
1*, 2, 3
1, 2, 3, 4**
1
* PDA applies to subgroup 1.
** Subgroups 4, if not tested shall be guaranteed to the limits specified in table I herein.
4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-
883 including groups A, B, C, and D inspections. The following additional criteria shall apply.
4.3.1 Group A inspection.
a. Tests shall be as specified in table II herein.
b. Subgroups 5, 6, 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
4.3.2 Groups C and D inspections.
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test conditions, method 1005 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1005 of MIL-STD-883.
(2) TA = +125°C, minimum.
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
B
5962-89637
SHEET
8