An internal RC oscillator with a following divider stage 1:210 allows a very long and
reproducible tracking time.
The RC values for the required final time, tt, can be calculated as follows:
Rt[Ω] = -1---.--6----×---t--s-1--[-s-0--]-2--×-4-----×1----0--C-6---t--[--µ---F----]
Ct[µF ]
=
------------t--s---[--s---]---×-----1----0---6-------------
1.6 × 1024 × Rt[Ω]
tt[s]
=
-C----t--[-µ----F---]----×-----R-----t--[--Ω----]----×------1---.--6-----×-----1----0---2---4--
106
Two AND-connected, identical inputs determine the trigger conditions of the monostable
time stages (Figure 8, Figure 9 on page 8), i.e., both inputs must be in position "ON" so
that the output is switched on. The tracking time starts after the trigger conditions have
elapsed. The output ON state is given until the tracking time has elapsed.
Input pin 5 is a simple comparator, whereas input pin 6 is designed as a window
discriminator.
The noise suppression for tON = 40 ms prevents peak noise signals at the inputs which
could trigger the circuit.
At the same time, the retrigger function is delayed for a duration of 640 ms (tOFF) to
avoid noise signal that may trigger the relay.
Figure 8. Trigger Condition, Pin 5
V5
0
T1 = 0.5 VRef
T2 = 0.65 VRef
VRef
OFF
Hysteresis
ON