Figure 4. Three-wire Circuit
L
Control
N
For three-wire switch systems, two operational modes are possible:
â Zero voltage switch operation for triac control
â Static operation for relay control
Mode Selection Pin 4 and The operational modes can be selected by the external voltage at the synchronous input
Supply Voltage Pin 2
pin 4 (clamping). The mode selection determines the current requirement of the relay's
or triac's driver stage and hence the selection of the supply voltage.
Zero Voltage Switch
Operation (Figure 5)
Selection condition:
V4 = internal synchronous limitation, without external clamping
R1 â
0.85
-V----M-----â-----V----S-
2 Itot
Itot = IS + Ip + IX
where:
IS = Supply current of the IC without load
IP = Average trigger current IG
IX = External circuit current requirement
VM = Mains voltage
Required firing pulse width tp
tp
=
2-Ï- arcsin
â
â
-IP-L-----ÃÃ-----V-----2M--â â
where:
IL = Triac latching current
P = Power at load Z
Rsync[kâ¦] â
-V----M----[--V----]---Ã----------2----s---i-n-----(---Ï----Ã------t--p---[-s---]---)---â-----0---.--7- â 176
1.8 Ã 10-2