TH02 Datasheet, PDF (7/26 Pages) List of Unclassifed Manufacturers – D IGITAL I 2C H UMIDITY AND TEMPERATURE S ENSOR
TH02
Table 5. Humidity Sensor
2.1 ≤ VDD ≤ 3.6 V; TA = 25 °C; tCONV = 35 ms unless otherwise noted.
Parameter
Operating Range1
Resolution2
Accuracy3,4
Symbol
Test Condition
Non-condensing
20–80% RH
Min
Typ
Max Unit
0
—
100 %RH
—
—
12
bit
—
±3.0
—
%RH
0–100% RH
See Figure 2
Repeatability—Noise
Response Time5
τ 63%
1 m/s airflow
—
0.05
—
%RH
RMS
—
8
—
s
Hysteresis
Long Term Stability4
—
±1
—
%RH
—
≤0.25
— %RH/yr
Notes:
1. Recommended humidity operating range is 20 to 80% RH (non-condensing) over 0 to 60 °C. Prolonged operation
beyond these ranges may result in a shift of sensor reading, with slow recovery time.
2. The TH02 has a nominal output of 16 codes per %RH, with 0h0000 = –24%RH.
3. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See section “4.2. Relative Humidity Sensor Accuracy” for more details.
4. May be impacted by dust, vaporized solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging
materials, etc. See section “4.10. Long Term Drift/Aging”.
5. Time for sensor output to reach 63% of its final value after a step change.
Table 6. Temperature Sensor
2.1 ≤ VDD ≤ 3.6 V; TA = 0 to 70 °C (F grade) or –40 to +85 °C (G grade); tCONV = 35 ms unless otherwise noted.
Parameter
Symbol
Test Condition
Min Typ Max
Operating Range
Resolution1
–40
—
85
—
—
14
Accuracy2
Typical at 25 °C
—
—
1/32
—
±0.5
—
Maximum
See Figure 3.
Repeatability—Noise
—
0.1
—
Response Time3
Long Term Stability
Time to reach 63% of final value
—
1.5
—
— <0.05 —
Unit
°C
Bit
°C
°C
°C
°C
RMS
s
°C/yr