TH02 Datasheet, PDF (7/26 Pages) List of Unclassifed Manufacturers – D IGITAL I 2C H UMIDITY AND TEMPERATURE S ENSOR | |||
|
◁ |
TH02
Table 5. Humidity Sensor
2.1 ⤠VDD ⤠3.6 V; TA = 25 °C; tCONV = 35 ms unless otherwise noted.
Parameter
Operating Range1
Resolution2
Accuracy3,4
Symbol
Test Condition
Non-condensing
20â80% RH
Min
Typ
Max Unit
0
â
100 %RH
â
â
12
bit
â
±3.0
â
%RH
0â100% RH
See Figure 2
RepeatabilityâNoise
Response Time5
Ï 63%
1 m/s airflow
â
0.05
â
%RH
RMS
â
8
â
s
Hysteresis
Long Term Stability4
â
±1
â
%RH
â
â¤0.25
â %RH/yr
Notes:
1. Recommended humidity operating range is 20 to 80% RH (non-condensing) over 0 to 60 °C. Prolonged operation
beyond these ranges may result in a shift of sensor reading, with slow recovery time.
2. The TH02 has a nominal output of 16 codes per %RH, with 0h0000 = â24%RH.
3. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See section â4.2. Relative Humidity Sensor Accuracyâ for more details.
4. May be impacted by dust, vaporized solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging
materials, etc. See section â4.10. Long Term Drift/Agingâ.
5. Time for sensor output to reach 63% of its final value after a step change.
Table 6. Temperature Sensor
2.1 ⤠VDD ⤠3.6 V; TA = 0 to 70 °C (F grade) or â40 to +85 °C (G grade); tCONV = 35 ms unless otherwise noted.
Parameter
Symbol
Test Condition
Min Typ Max
Operating Range
Resolution1
â40
â
85
â
â
14
Accuracy2
Typical at 25 °C
â
â
1/32
â
±0.5
â
Maximum
See Figure 3.
RepeatabilityâNoise
â
0.1
â
Response Time3
Long Term Stability
Time to reach 63% of final value
â
1.5
â
â <0.05 â
Unit
°C
Bit
°C
°C
°C
°C
RMS
s
°C/yr
Tel:+86-755-82973805 Fax: +86-755-82973550 Email:sales@hoperf.com http://www.hoperf.com