TH02
2.3. Linearization
Capacitive relative humidity sensors require linearization. The TH02 accuracy specification applies after correction
of non-linearity errors. The recommended linearization technique is to correct the measured relative humidity
value with a 2nd order polynomial; the linear relative humidity (RH) value is calculated as follows:
RHLinear = RHValue – ((RHValue)2 × A2 + RHValue × A1 + A0)
Where:
RHLinear is the corrected relative humidity value in %RH
RHValue is the uncorrected (measured) relative humidity value in %RH
A2, A1, and A0 are unit-less correction coefficients derived through characterization of TH02s
their values depend on whether compensation for a typical solder reflow is required
The values for the correction coefficients are shown in Table 8.
Table 8. Linearization Coefficients
Coefficient
A0
A1
A2
Value
–4.7844
0.4008
–0.00393