CONVERSION SEQUENCE
A conversion has to be started by sending this command. The sensor stays busy until conversion is
done. When conversion is finished the data can be accessed by using ADC read command
SPI
The last clock will start the conversion which TSYS01 indicates by pulling SDO low. SDO goes high
when conversion is completed.
I2C
When the command is sent the TSYS01 stays busy until the conversion is done. All other commands
except the reset command will not be executed during this time. When the conversion is finished the
data can be accessed by sending a ADC read command, when an acknowledge appears from TSYS01.
READ ADC RESULT
After the conversion command the ADC result is read using ADC read command. Repeated ADC read
commands, or command executed without prior conversion will return all 0 as result.