English
Language : 

BXRA-35E4000 Datasheet, PDF (7/24 Pages) List of Unclassifed Manufacturers – Bridgelux RS Array Series
Flux Characteristics
Color
Warm
White
Neutral
White
Cool
White
Table 2: Flux Characteristics
ANSI
CCT
(K)
2700
3000
3500
4000
5000
5600
Base Part Number
BXRA-27E4000-H-00
BXRA-27G4000-H-00
BXRA-27E7000-J-00
BXRA-27G7000-J-00
BXRA-30E4000-H-00
BXRA-30G4000-H-00
BXRA-30E7000-J-00
BXRA-30G7000-J-00
BXRA-35E4000-H-00
BXRA-35E7000-J-00
BXRA-40E4500-H-00
BXRA-40E7500-J-00
BXRA-50C5300-H-00
BXRA-50C9000-J-00
BXRA-56C5300-H-00
BXRA-56C9000-J-00
CRI
(min) (4)
80
90
80
90
80
90
80
90
80
80
80
80
70
70
70
70
Typical
DC Flux
Tcase= 70ºC
(lm)(3)
3980
3400
6190
5270
4230
3715
6580
5790
4560
7110
4830
7500
5370
8560
5370
8560
Minimum
Pulsed
Flux
Tj = 25ºC
(lm)(1)
4000
3400
6350
5400
4250
3750
6750
5950
4600
7300
4850
7700
5400
8800
5400
8800
Typical
Pulsed
Flux
Tj = 25ºC
(lm)
4450
3800
7050
6000
4725
4150
7500
6600
5100
8100
5400
8550
6000
9750
6000
9750
Test
Current
(mA)(2)
2100
2100
2800
2800
2100
2100
2800
2800
2100
2800
2100
2800
2100
2800
2100
2800
Notes for Table 2:
1. Bridgelux maintains a ± 7% tolerance of flux measurements.
2. Parts are tested in pulsed conditions, Tj = 25°C. Pulse width is 10 ms at rated test current.
3. Typical performance when driven at DC (direct current) test current with LED Array case
temperature maintained at 70°C, mounted to heat sink with thermal interface material. Please
contact a Bridgelux sales representative for additional details.
4. Typical R9 value for 90 CRI product options is 50.
5. Reference Table 7 and 8 for typical performance at other driver currents (including those
commonly available in the market).
Bridgelux RS Array Series Product Data Sheet DS25 (12/3/11)
Page 7 of 24