English
Language : 

T-51513D104J-FW-A-AD Datasheet, PDF (6/17 Pages) List of Unclassifed Manufacturers – LCD Module Technical Specification
*1) Lamp Current measurement method (The current meter is inserted in low voltage line.)
CTL
A
LCD
Module
CTH
A
CTL
CTH
Inverter
Power
Supply
*2) Lamp frequency of inverter may produce interference with horizontal synchronous frequency, and
this may cause horizontal beat on the display. Therefore, please adjust lamp frequency, and keep
inverter as far from module as possible or use electronic shielding between inverter and module to
avoid the interference.
*3) Lamp life time is defined as the time either when the brightness becomes 50% of the initial value, or
when the starting lamp voltage does not meet the value specified in this table.
*4) The life time of the backlight depends on the ambient temperature. The life time will decrease under
low/high temperature.
*5) Please use the inverter which has symmetrical current wave form as follows,
The degree of unbalance: less than 10%
The ratio of wave height: less than 2 ±10%
IPH
IPH: High side peak
The degree of unbalance = |IPH - IPL| / Irms × 100(%)
IPL
IPL: Low side peak The ratio of wave height = IPH(or IPL) / Irms
CURRENT WAVE FORM
T-51513D104J-FW-A-AD (AD) No. 2004-0193
OPTREX CORPORATION