English
Language : 

BXRC-20B1001-B-73 Datasheet, PDF (6/31 Pages) List of Unclassifed Manufacturers – Bridgelux Gen 7 Vero 10 Array Series
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
BXRC-35A1001-B-738,9
BXRC-35A1001-C-738,9
BXRC-35A1001-D-738,9
BXRC-40E1000-B-7X
BXRC-40E1000-C-7X
BXRC-40E1000-D-7X
BXRC-40G1000-B-7X
BXRC-40G1000-C-7X
BXRC-40G1000-D-7X
BXRC-40A1001-B-738,9
BXRC-40A1001-C-738,9
BXRC-40A1001-D-738,9
BXRC-50C1001-B-7x
BXRC-50C1001-C-7x
BXRC-50C1001-D-7x
BXRC-50E1001-B-7x
BXRC-50E1001-C-7x
BXRC-50E1001-D-7x
BXRC-50G1001-B-7x
BXRC-50G1001-C-7x
BXRC-50G1001-D-7x
BXRC-57C1001-B-7x
BXRC-57C1001-C-7x
BXRC-57C1001-D-7x
BXRC-57E1001-B-7x
BXRC-57E1001-C-7x
BXRC-57E1001-D-7x
BXRC-65C1001-B-7x
BXRC-65C1001-C-7x
BXRC-65C1001-D-7x
BXRC-65E1001-B-7x
BXRC-65E1001-C-7x
BXRC-65E1001-D-7x
Nominal
CCT1
(K)
3500
3500
3500
4000
4000
4000
4000
4000
4000
4000
4000
4000
5000
5000
5000
5000
5000
5000
5000
5000
5000
5700
5700
5700
5700
5700
5700
6500
6500
6500
6500
6500
6500
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
93
270
93
360
93
350
80
270
1170
1560
1138
1461
1030
1373
1001
1285
80
360
1947
1713
80
350
1420
1249
90
270
1250
1100
90
360
1666
1466
90
350
93
270
93
360
93
350
70
270
1215
1245
1660
1210
1601
1069
1096
1461
1065
1409
70
360
2134
1878
70
350
1556
1369
80
270
1505
1324
80
360
2006
1765
80
350
1463
1287
90
270
1281
1127
90
360
1707
1502
90
350
1245
1095
70
270
1545
1360
70
360
2059
1812
70
350
1502
1321
80
270
1531
1347
80
360
2040
1796
80
350
1488
1309
70
270
1573
1384
70
360
2097
1845
70
350
1529
1345
80
270
1559
1372
80
360
2078
1829
80
350
1515
1333
Typical Vf
(V)
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
Typical
Power
(W)
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
Typical
Efficacy
(lm/W)
125
125
125
155
155
156
133
133
134
133
133
133
170
170
171
160
160
161
136
136
137
164
164
165
163
163
164
167
167
168
166
166
167
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80
CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93 . Bridgelux maintains a ± 3 tolerance
on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
4