Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
BXRC-20B1001-B-73
2000
65
270
BXRC-20B1001-D-73
2000
65
350
BXRC-27E1000-B-7X
2700
80
270
BXRC-27E1000-C-7X
2700
80
360
BXRC-27E1000-D-7X
2700
80
350
BXRC-27G1000-B-7X
2700
90
270
BXRC-27G1000-C-7X
2700
90
360
BXRC-27G1000-D-7X
2700
90
350
BXRC-27H1000-B-7x
2700
97
270
BXRC-27H1000-C-7x
2700
97
360
BXRC-27H1000-D-7x
2700
97
350
BXRC-30E1000-B-7X
3000
80
270
BXRC-30E1000-C-7X
3000
80
360
BXRC-30E1000-D-7X
3000
80
350
BXRC-30G1000-B-7X
3000
90
270
BXRC-30G1000-C-7X
3000
90
360
BXRC-30G1000-D-7X
3000
90
350
BXRC-30G100C-B-73
3000
90
270
BXRC-30G100C-D-73
3000
90
350
BXRC-30H1000-B-7x
3000
97
270
BXRC-30H1000-C-7x
3000
97
360
BXRC-30H1000-D-7x
3000
97
350
BXRC-30A1001-B-738,9
3000
93
270
BXRC-30A1001-C-738,9
3000
93
360
BXRC-30A1001-D-738,9
3000
93
350
BXRC-35E1000-B-7X
3500
80
270
BXRC-35E1000-C-7X
3500
80
360
BXRC-35E1000-D-7X
3500
80
350
BXRC-35G1000-B-7X
3500
90
270
BXRC-35G1000-C-7X
3500
90
360
BXRC-35G1000-D-7X
3500
90
350
1328
1284
1348
1797
1310
1124
1498
1092
984
1311
956
1418
1890
1365
1166
1554
1133
1092
1056
1054
1404
1024
1086
1448
1056
1447
1928
1406
1208
1610
1174
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
1169
1130
1187
1581
1153
989
1318
961
866
1154
841
1247
1663
1201
1026
1367
997
961
929
927
1236
901
956
1274
929
1273
1697
1237
1063
1417
1033
Typical Vf
(V)
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
35.0
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
34.8
34.8
26.0
Typical
Power
(W)
9.4
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
Typical
Efficacy
(lm/W)
141
141
144
143
144
120
120
120
105
105
105
151
151
150
124
124
125
116
116
112
112
113
116
116
116
154
154
155
129
129
129
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value
for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3
tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
3