English
Language : 

ATX0200 Datasheet, PDF (6/11 Pages) List of Unclassifed Manufacturers – specification describes the requirements of 300W,350W,400W,450W,500W, 550W,600W active P.F.C Switching Power Supply
_E_n_h_a_n_c_e_E_l_e_c_tr_o_n_ic_s__C_o_.,_L_T_D__________________________________________________________________P_ro_d_u_c_t_S_p_e_c_i_fi_c_a_ti_on
2.3.2 Definition
The ripple voltage of the outputs shall be measured at the pins of the output connector
when terminated in the load impedance specified in figure 1. Ripple and noise are measured
at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate
system loading.Ripple shall be measured under any condition of line voltage,output load,line
frequency,operation temperature.
2.3.3 Fignre3. Ripple/Noise voltage test circuit
Power Supply
AC H ot
AC Neutra l
V out
V re tu rn
AC Grou nd
10uF 0.1uF
Load
Scope
Figure 3. Ripple/Noise voltage test circuit
2.4 Overshoot
Any overshoot at turn on or turn off shall be less 10% of the nominal voltage value, all outputs shall be within
the regulation limit of section 2.0 before issuing the power good signal of section 5.0.
2.5 Efficiency
Power supply typical efficiency is 80% under full Load at nominal input voltage of 115VAC or 230VAC.
2.6 Remote on/off control
When the logic level "PS-ON" is low, the DC outputs are to be enabled.
When the logic level is high or open collector, the DC outputs are to be disabled.
 3. PROTECTION
3.1 Over-power protection
The power supply will be shutdown and latch off when output power is 110%~160%.
3.2 Over voltage protection
The over voltage sense circuitry and reference shall reside in packages that are separate and distinct
from the regulator control circuity and reference.No single point fault shall be able to cause a sustained
over voltage condition on any or all outputs.The supply shall provide latch-mode over voltage protection
as defined in Table.
output
+12 V1DC or +12V2DC
+5 VDC
+3.3 VDC
Minimum
13.4
5.74
3.76
Nominal
15.0
6.3
4.2
Maximum
17
7.5
4.8
Unit
Volts
Volts
Volts
3.3 Over Current Protection(300W)
+5VDC' and '+3.3VDC' have separate over current protection circuits to
meet 240VA safety requirement.
Parameter
Min.
Max.
Unit
+12V1
14
30
A
+12V2
13
30
A
AUDIT:_________李復新____________CHECK:____________________DESIGN:____ 邢小燕_____________
ATX0200(80PLUS).SPEC REV:30
6 OF 11
2010/04/15