English
Language : 

ATX0200 Datasheet, PDF (3/11 Pages) List of Unclassifed Manufacturers – specification describes the requirements of 300W,350W,400W,450W,500W, 550W,600W active P.F.C Switching Power Supply
_E_n_h_a_n_c_e_E_l_e_c_tr_o_n_ic_s__C_o_.,_L_T_D__________________________________________________________________P_ro_d_u_c_t_S_p_e_c_i_fi_c_a_ti_on
Table5 Typical Power Distribution for a 350W ATX12V Configuration
Parameter
Min
Nom.
Max
Peak
Unit
+12V1DC
0.1
-
11.0
15.0
Amps
+12V2DC
0.5
-
14.0
18.0
Amps
+5VDC
0.2
-
15.0
-
Amps
+3.3VDC
0.1
-
21.0
-
Amps
-12VDC
0.0
-
0.3
-
Amps
+5VSB
0.0
-
2.5
3.5
Amps
Note:
1. Total combined output of 3.3V and 5V is ≦103W
2. Total combined output of +12V1&+12V2 is ≦265W
3. Peak currents may last up to 17 seconds with not more than one occurrence per minute requirements.
2.2.3 Table5 Typical Power Distribution for a 400W ATX12V Configuration
Table5 Typical Power Distribution for a 400W ATX12V Configuration
Parameter
Min
Nom.
Max
Peak
Unit
+12V1DC
0.1
-
18.0
19.0
Amps
+12V2DC
0.5
-
18.0
19.0
Amps
+5VDC
0.2
-
20.0
-
Amps
+3.3VDC
0.1
-
24.0
-
Amps
-12VDC
0.0
-
0.3
-
Amps
+5VSB
0.0
-
2.5
3.5
Amps
Note:
1. Total combined output of 3.3V and 5V is ≦120W
2. Total combined output of +12V1&+12V2 is ≦300W
3. Peak currents may last up to 17 seconds with not more than one occurrence per minute requirements.
4.When +12V1 & +12V2 load is over 20A,+5V min load is 0.5A
5. When +5V load is over 16A,+12V1 & +12V2 min load is 20A.
2.2.4 Table5 Typical Power Distribution for a 450W ATX12V Configuration
AUDIT:_________李復新____________CHECK:____________________DESIGN:____ 邢小燕_____________
ATX0200(80PLUS).SPEC REV:30
3 OF 11
2010/04/15