ATV32H055N4 Datasheet, PDF (6/10 Pages) List of Unclassifed Manufacturers – variable speed drive ATV32
Product data sheet
Connections and Schema
ATV32H055N4
Connection Diagrams
Single or Three-phase Power Supply - Diagram with Line Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1.
(1) Line choke (if used)
(3) Fault relay contacts, for remote signaling of drive status
Single or Three-phase Power Supply - Diagram with Switch Disconnect
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1.
(1) Line choke (if used)
(3) Fault relay contacts, for remote signaling of drive status
Diagram with Preventa Safety Module (Safe Torque Off Function)
Connection diagrams conforming to standards EN 954-1 category 3 and IEC/EN 61508 capacity SIL2, stopping category 0 in accordance
with standard IEC/EN 60204-1.
When the emergency stop is activated, the drive power supply is cut immediately and the motor stops in freewheel, according to category 0
of standard IEC/EN 60204-1.
A contact on the Preventa XPS AC module must be inserted in the brake control circuit to engage it safely when the STO (Safe Torque Off)
safety function is activated.
6