SGM70XX Datasheet, PDF (5/9 Pages) List of Unclassifed Manufacturers – Pressure independent & temperature compensated
2.2 Interface
Digital 2-wire interface (standard I2C) with bus clock frequency of 100 kHz (Maximum 400 kHz)
Default I2C address: 64 (binary 1000 000)
2.3 Electromagnetic compatibility (EMC)
To be tested within the final gas meter product.
2.4 Preventions against electrostatic discharge (ESD)
The inherent design of this component causes it to be sensitive to electrostatic discharge (ESD). To prevent ESD-induced
damage and/or degradation, take common and statutory ESD precautions when handling this product.
3. Mechanical Specifications
3.1 Mechanical dimensions SGM7001 and SGM7002
Dimensions are given in mm.
www.sensirion.com
5/9