English
Language : 

HP206C Datasheet, PDF (3/17 Pages) List of Unclassifed Manufacturers – PRECISION BAROMETER AND ALTIMETER SENSOR
DataSheet
HP206C
Table2: Temperature Output Characteristics @ VDD = 3.0V, T = 25°C unless otherwise noted
Parameter
Symbol
Conditions
Min Typ Max Unit
Operation Temperature
Range
TOP
Temperature Absolute
Accuracy
Max Error with Power
Temperature Resolution of
Output Data
-40
25℃
-10℃ to +70℃
-40℃ to + 85℃
Power supply from 1.8V to 3.6V
85 ℃
±0.3 ±0.5 ℃
±0.6 ±1.0 ℃
±1.0 ±1.5 ℃
±0.5 ℃
0.01
℃
2.2 Electrical Characteristics
Table3: DC Characteristics @VDD=3.0 V, T=25℃ unless otherwise note
Parameter
Symbol
Conditions
Min
Operation Supply Voltage VDD
Operation Temperature TOP
Average Operation Current
(Pressure Measurement IDDAVP
under One Conversion per
Second)
Average Operation Current
(Temperature
Measurement under One
IDDAVT
Conversion per Second)
Conversion Time of
Pressure or Temperature
tCONV
Peak Current
IPEAK
Standby Supply Current
Serial Data Clock
Frequency
IDDSTB
fSCLK
Digital Input High Voltage VIH
Digital Input Low Voltage VIL
Digital Output High
Voltage
VOH
Digital Output Low
Voltage
VOL
Input Capacitance
CIN
*OSR stands for over sampling rate
1.8
-40
OSR*
OSR*
OSR*
4096
2048
1024
512
256
128
4096
2048
1024
512
256
128
4096
2048
1024
512
256
128
During conversion
At 25℃
I2C protocol, pull-up resistor of 10k
0.8
IO = 0.5 mA
0.9
IO = 0.5 mA
Typ. Max
3.0 3.6
85
85.2
42.6
21.3
10.7
5.3
2.7
68.8
34.4
17.2
8.6
4.3
2.2
65.6
32.8
16.4
8.2
4.1
2.1
1.3
0.1
100 400
0.2
0.1
4.7
Unit
V
℃
μA
μA
ms
mA
μA
kHz
V
V
V
V
pF
HP206C_DataSheet_EN_V2.0
www.hoperf.com
3 / 17