HP206C Datasheet, PDF (15/17 Pages) List of Unclassifed Manufacturers – PRECISION BAROMETER AND ALTIMETER SENSOR
DataSheet
HP206C
an interrupt is being cleared by an ADC reading command, it goes low while the data is being sent back from
the device to the external MCU.
6.4 Enable the Compensation
PARA - (RW)
This register has only one valid bit of CMPS_EN. The user can use this bit to determine whether to enable
the data compensation during the conversion process (0: disable, 1: enable). If it is enabled, the 24-bit or
48-bit data read out by the commands are fully compensated. If it is disabled, the data read out are the raw
data output.
7. Typical Application Circuit
Figure3: Typical application circuit