F 6.0 SAFETY
6.1 Underwriters Laboratory (UL) listee.
The power supply designed to meet UL 60950.
6.2 Canadian Standards Association(CSA) approval.
The power supply designed to meet CSA C22.2 NO. 950.
6.3 The power supply must be certified to EN60 950, A1 and A2.
6.4 CB test report to meet the IEC 60950.
6.5 NEMKO certified by any NORDIC CENELEC.
6.6 The power supply must bear the German Bauart Mark from TUV/GS.
F 7.0 ELECTROMAGNETIC COMPATIBILITY (EMC)
7.1 IEC 801-2 ESD (IEC 1004-4-2)
7.2 IEC 801-3 Radiated electrical field requirement (IEC 1004-4-3)
7.3 IEC 801-4 BURST (IEC 1004-4-4)
7.4 IEC 801-5 Surge Voltages
7.5 EN60555-2 harmonic current emissions
7.6 EN55022 Class B Radio interference (CISPR 22)
7.7 FCC Part 15, Subpart J class B 115VAC operation.
F 8.0 MTBF ( MEAN-TIME-BETWEEN FAILURES ) CALCULATION
The demonstrated MTBF shall be 70,000 hours of continuous operation at 25oC,
Full load. 80% confidence limit and nominal line.The MTBF of the power supply
shall be calculated in accordance with MIL-STD-217F.
AUDIT:__________________CHECK:____________________DESIGN:____________________