English
Language : 

ZSSC3008 Datasheet, PDF (29/47 Pages) List of Unclassifed Manufacturers – Sensor Signal Conditioner with Diagnostics
ZSSC3008
Sensor Signal Conditioner with Diagnostics
3.3. Command/Data Bytes Encoding
The 2-byte command sent to the ZSSC3008 consists of 1 byte of command information and 1 byte of data
information. Regardless of whether the command requires data or not, 2 bytes MUST be sent. Table 3.4 lists all
the command/data pairings. (X=don’t care.)
Table 3.4 Command/Data Bytes Encoding
Command
Byte
00H
20H
Data
XXH
5XH
30H
40H
00H
40H
10H
50H
90H
60H
YYH
80H
YYH
90H
YYH
A0H
YYH
B0H
YYH
08H
YYH
Description
Read EEPROM command via SIG™ pin.†
DAC Ramp Test Mode. Gain_B[13:3] contains the starting point, and the increment is
(Offset_B/8). The increment will be added every 125µsec.
Trim/Configure: 3rd nibble determines what is trimmed/configured. The 4th nibble is data to be
programmed.
3rd Nibble
4th Nibble
Description
0H
Data
Trim oscillator. Least significant 3 bits of data used.
1H
Data
Trim 1V reference. Least significant 4 bits of data used.
2H
Data
Offset Mode. Least significant 4 bits of data used.
3H
Data
Set output mode. Least significant 2 bits used.
4H
Data
Set update rate. Least significant 2 bits used.
5H
Data
Configure JFET regulation
7H
Data
Program EEPROM bits [99:96] (Pamp_Gain)
DH
Program EEPROM bits [105:103]:
3H or 6H
EEPROM locked! All others: EEPROM unlocked.
EH
Data
Program EEPROM bits [102:100] diag_cfg ‡
Start NOM => Ends Command Mode; transition to Normal Operation Mode.
Start_RM = Start the Raw Mode (RM)
In this mode, if Gain_B = 800H, then the digital output will simply be the raw values of the ADC
for the Bridge reading.
Start_CM => Start the Command Mode; used to enter Command Interpret Mode.
Program SOT (2nd Order Term)
Program Gain_B upper 7-bits (Set the MSB to 0.)
Program Gain_B lower 8-bits
Program Offset_B upper 6-bits (Set the two MSBs to 0.)
Program Offset_B lower 8-bits
Program Upper Clipping Limit (Set the MSB to 0.)
† For more details, refer to section 3.7.
‡ For more details, refer to section 3.5.
Data Sheet
June 14, 2011
© 2011 Zentrum Mikroelektronik Dresden AG — Rev. 1.11
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without
the prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice.
29 of 46