Addr. Register Name Default Bits Variable Name
0x0A PllStat
0x10
7:6 -
5 pll_lock_detect
4 pll_cal_done
3 pll_cal_ok
0x0B VcoCtrl1
0x0C VcoCtrl2
0x0D VcoCtrl3
0x0E VcoCtrl4
0x0F ClockCtrl
2 pll_cal_start
1:0 pll_divr(1:0)
NA
NA
NA
NA
0x05
7:5 -
4:0 SB1(4:0)
7:5 -
4:0 SB2(4:0)
7:5 -
4:0 SB3(4:0)
7:5 -
4:0 SB4(4:0)
7:4 -
3 rc_enable
2:0 clkout_select
Mode
Description
r unused
r PLL lock status:
0 = PLL not locked
1 = PLL locked
r PLL calibration status
0 = Calibration on-going
1 = Calibration performed
Note: Reset to 0 in sleep mode irrespective of
calibration state.
r PLL Calibration Result
0 = Calibration procedure failed
1= Calibration procedure successful
Note: Reset to 0 in sleep mode irrespective of
calibration state
w Triggers PLL calibration, always read as 0.
rw PLL division ratio
00 = Automatic
Others, PLL divider = PLL_divr
r unused
rw VCO band first calibration value
r unused
rw VCO band second calibration value
r unused
rw VCO band third calibration value
r unused
rw VCO band fourth calibration value
r unused
rw Enables RC oscillator. RC oscillator is also
automatically switched on in E2PROM mode.
0 = RC oscillator off
1 = RC oscillator on
rw Selects CLKOUT source:
000 = fXOSC (32 MHz)
001 = fXOSC / 2 (16 MHz)
010 = fXOSC / 4 (8 MHz)
011 = fXOSC / 8 (4 MHz)
100 = fXOSC / 16 (2 MHz)
101 = fXOSC / 32 (1 MHz) (d)
110 = RC clock (65 kHz)
111 = Clock output off.
Note: Switching from RC to fXOSC or vice versa
can generate glitches
Page 24