EA eDIP128-6
Page 21
DISPLAY BLINK MODE
After power on or the command 'ESC DG 0' the eDIP128 is in blink mode.
Two picture contents are alternatly shown in an adjustable period.
Blink attributs are set by the commands 'ESC ZB, UB, GB n1':
n1=0: no blink
n1=1: On/Off blink
n1=2: blink inverted
n1=3: Off/On blink (phase shifted)
Between strings ('ESC ZL,ZC,ZR. ..), flashing can be activated locally:
Strings between two ‘~’ ($7E) mean blink on/off.
Strings between two ‘&’ ($26) mean blink off/on phase shifted.
Strings between two '@' ($40) mean blink inverted.
In addition you can assign or delete postly an rectangle area a blink mode, by using the command
'ESC Q...'