IAG4-39221-1 Datasheet, PDF (20/24 Pages) List of Unclassifed Manufacturers – Magnetic Circuit Protectors
IAG/IUG/IEG/CEG DECISION TABLES
The ordering code for IAG/IUG/IEG/CEG/IDG circuit
protectors may be determined by following the
decision steps in the tables shown here.
The coding given permits a self-assigning part
number but with certain limitations. Special
applications may require a factory-assigned part
number. Typical examples are units with mixed
ratings, combinations of styles, or constructions not
listed in the third decision table. With these, it is
suggested that order entry be by description and/or
drawings and a part number will be established.
Additionally, it is standard policy to establish a
factory-assigned part number whenever a
descriptive drawing exists to provide cross
reference, traceability and manufacturing control.
When specifying a circuit protector for AC motor
start or high inrush applications, the peak
amplitude and surge duration should be specified
for factory assistance in rating selection.
For example, the following is the code for a single
pole, IEG quick-connect type terminal, series unit
with auxiliary switch, designed for operation in a
50/60Hz circuit. It has a short time delay, a rating of
20 amperes, a black marked handle and is VDE
approved.
To determine the ordering number for your
particular IAG/IUG/IEG/CEG unit, simply follow the
steps shown. You may use this number to place an
order or as a reference for further questions you
may have.
Notes:
A. It is recommended that power leads be soldered to circuit
protectors having push-on type terminals for current trip
ratings above 20 amperes.
B. When “A” (metric thread mounting) is specified in the sixth
decision in combination with screw terminal option in the
second decision, metric screw terminals are supplied.
C. IEG, IEGH, IEGS, IEGHS, IEGX and IEGZX circuit protectors are
designed to meet 8mm creepage and clearance requirements
for installation Category III, Pollution Degree 3, Case A as
measured in IEC 664. Intended for use in equipment designed
to comply with IEC 601 and 950 and VDE 0804
and 0805.
1 First Decision
Select Type and Terminal
Type
Description
IAG
IUG*
IEG**
CUG+
CEG++
IAGH
IUGH*
IEGH**
CUGH+
CEGH++
IDG***
One toggle handle per unit
One toggle handle per pole
One toggle handle per unit,
marine ignition protection
IDGH***
One toggle handle per pole
marine ignition protection
IMG** One toggle handle per unit
CMG++ mid-trip indication
IMGH** One toggle handle per pole
CMGH++ mid-trip indication
*UL Recognized, CSA Certi ed
**UL Recognized, CSA Certi ed, VDE Approved
*** UL Recognized UL1500
+ UL489A Listed CSA Certi ed
++ UL489AListed CSA Certi ed VDE Approved
Handle and Mounting Options
Standard toggle/mounting,
no designation required
S Toggle w/ snap-in mounting
X Rocker w/ standard mounting*
ZX ZX Rocker w/ integral mounting*
BX BX Rocker w/ integral mounting
N Sealed toggle w/bushing mounting**
Note: Add "F" for at screw terminals
* Not available on mid-trip units
** Available only on IAG, IUG units
2 Second Decision
Poles and Terminals
Push-on
Terminals
1
Screw
Terminals
6
Single pole
11
66
Two pole
111
666
Three pole
1111
6666
Four pole
*Not available in toggle seal handle type.
Example:
IEG 1 - 1REC4 - 61 - 20.0
- 01 - V
12 3 4 567
3 Third Decision
Internal Con guration
-0
Switch only
-1
Series
-1REC4 Series w/ auxiliary switch *
.110 quick connect
-1REC5 Series w/ auxiliary switch *
.187 quick connect
-1REG4 Series w/ auxiliary switch
(gold contacts)*
.110 quick connect
-1RS4
Series w/ alarm switch,
electrical trip,
.110 Q.C. terminals
-1RLS4
Series w/ alarm switch,
electrical trip,
.110 Q.C. terminals (mid-trip only)
-3
Shunt
-4
Relay
* Only one auxiliary switch is normally supplied on two or
three pole units. Switch is located in the right-hand pole
(viewed from terminal end) unless otherwise speci ed.
4 Fourth Decision
Frequency and Delay
SW Switch only
-41 400Hz short delay
-42 400Hz long delay
-43 400Hz motor start
-49 400Hz 150% instant trip
-51 DC short delay*
-52 DC long delay*
-53 DC motor start*
-59 DC 125% instant trip*
-61 50/60Hz short delay
-62 50/60Hz long delay
-63 50/60Hz motor start
-64 50/60Hz short delay
-65 50/60Hz long delay
-66 50/60Hz motor start
-69 50/60Hz 125% instant trip
-71 DC/60Hz short delay
-72 DC/60Hz long delay
-73 DC/60Hz motor start
-79 DC/60 Hz 135% instant trip
For addition of inertial delay, add an ìFî to any
delay numeral.
* CEG types are only available with DC ratings
C = CCC Approved
This approval requires the addition of a C at the end
of the part number. The unit will not be VDE Approved.
V = VDE and CCC Approved
The shaded areas denote VDE and CCC (if applicable)
approval options. This approval requires the addition of a V
at the end of the part number. The V will be added to any
part number formed entirely from shaded decisions.
If non-shaded areas are selected, the unit will not be VDE or
CCC Approved, but other approvals still apply.
117 IAG Series - Decision Tables