IAG4-39221-1 Datasheet, PDF (13/24 Pages) List of Unclassifed Manufacturers – Magnetic Circuit Protectors
TYPICAL RESISTANCE / IMPEDANCE
Impedance
Current Ratings
(Amps)
DC
(ohms)
AC, 50/60Hz AC, 400Hz
(ohms)
(ohms)
51, 52, 53, 59 61, 62, 63, 69 41, 42, 43, 49
0.200
45.8
28.5
71.94
1.00
1.38
1.10
2.85
2.00
0.371
0.29
0.76
5.00
0.055
0.051
0.12
10.0
0.017
0.016
0.032
20.0
0.006
0.006
0.010
30.0
0.003
0.004
0.006
50.0
0.0019
0.0018
—
DCR and Impedance based on 100% rated current applied and stabalized for
a minimum of one hour. Tolerance .05-2.5 amperes ± 20%: 2.6 -20 amperes
± 25%, 21-50 amperes ± 50%. Consult factory for special values and for coil
impedance of delays not shown.
OPERATING CHARACTERISTICS
Inrush Pulse Tolerance
The following table provides a comparison of inrush
pulse tolerance with and without the inertial delay
feature for each of the 50/60Hz delays. Pulse
tolerance is defined as a single pulse of half sine
wave peak current amplitude of 8 milliseconds
duration that will not trip the circuit breaker. The
table at left provides a guide to determine if the
inertia delay feature is required. Consult factory for
further assistance.
INRUSH PULSE TOLERANCE
Delay
61, 62, 63, 71, 72, 73
61F, 62F, 63F, 71F, 72F, 73F
64, 65, 66
Pulse Tolerance
10 times rated current (approx)
12 times rated current (approx)
25 times rated current (approx)
PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT)
Delay
100%
125%
150%
200%
400%
600%
41
No Trip
May Trip
.500 to 8.0 .150 to 1.9 .020 to .40 .006 to .25
42
No Trip
May Trip
5 to 70
2.2 to 25
.40 to 5.0
.012 to 2
43
No Trip
May Trip
35 to 350
12 to 120
1.5 to 20 .012 to 2.2
49
No Trip
May Trip
.100 Max
.050 Max
.020 Max
.020 Max
51*
No Trip
.500 to 6.5 .300 to 3.0 .100 to 1.2 .031 to .500 .011 to .25
52*
No Trip
2 to 60
1.8 to 30
1 to 10
.15 to 2.0
.04 to 1
53*
No Trip
80 to 700
40 to 400
15 to 150
2 to 20
.23 to 9
59*
No Trip .120 Max .050 Max .050 Max .022 Max .017 Max
61*
No Trip
.700 to 12 .35 to 7.0 .130 to 3.0 .030 to 1
.015 to .3
62*
No Trip
10 to 120
6 to 60
2 to 20
.2 to 3.0
.02 to 2
63*
No Trip
50 to 700
30 to 400
10 to 150
1.5 to 20
.4 to 10
64
No Trip
.7 to 12
.35 to 7
.13 to 3
.030 to 1
.017 to .3
65
No Trip
10 to 120
6 to 60
2 to 20
.2 to 3
.02 to 2
66
No Trip
50 to 700
30 to 400
10 to 150
1.5 to 20
.4 to 10
69*
No Trip .120 Max .100 Max .050 Max .022 Max .017 Max
71**
No Trip .440 to 10
.300 to 7 .100 to 3.0
.03 to 1
.012 to .3
72**
No Trip 1.8 to 100 1.7 to 60
1 to 20
.15 to 3
.04 to 2
73**
No Trip
50 to 600 30 to 400 10 to 150
1.8 to 20
.22 to 10
79**
No Trip .120 Max .100 Max .050 Max .023 Max .016 Max
*CEG type units are available only with 51, 52, ,53 and 59 delays LEG type units are available only with 61, 62, 63 and 69 delays
**135% minimum trip point for delays 71, 72, 73 and 79
800%
.004 to .1
.006 to .2
.01 to .22
.020 Max
.004 to .1
.008 to .5
.018 to .55
.017 Max
.01 to .15
.015 to .8
.013 to .85
.01 to .16
.017 to .76
.014 to 5
.017 Max
.004 to .15
.008 to .79
.018 to .88
.015 Max
1000%
.004 to .05
.006 to .15
.01 to .1
.020 Max
.004 to .08
.006 to .1
.012 to .2
.017 Max
.008 to .1
.01 to .25
.013 to .5
.008 to .1
.01 to. 6
.014 to 3
.017 Max
.004 to .1
.006 to .28
.011 to .50
.015 Max
IAG Series - Operating Characteristics 110