English
Language : 

SGM7001 Datasheet, PDF (2/9 Pages) List of Unclassifed Manufacturers – Pressure independent & temperature compensated
 Test gas meter in air only
Every SGM70xx sensor is individually pre-calibrated,
linearized and temperature compensated with air and a
surrogate gas of methane. The automatic gas quality
compensation can either be configured for measurements
in H-gas or L-gas.
The customer needs to fine-adjust meter calibration in air
only. No further calibration or testing with natural gas on
the customer side is needed. Sensirion provides
consulting and support regarding fine-adjustment of
calibration.
1. Sensor Performance1
Sensor performance is described for fine-adjusted product in template gas meter housing. Please note that a sensor built in
customer meter housing can achieve inhere specified performance only after fine-adjustment procedure.
1.1 Specification of Flow Rates
Qmin
Qt
Qmax
Qsaturation3
Qoverflow4
neg. saturation
pos. saturation
Qreverse5
SNR6 @ 0.25 Qmin
(relevant for min. detectable flow rate)
Unit
slm (2)
scmh (2)
slm (2)
scmh (2)
slm (2)
scmh (2)
slm (2)
slm (2)
SGM7001
0.267
0.016
4.17
0.25
41.67
2.5
-9
53
SGM7002
0.416
0.025
6.66
0.4
66.7
4.0
-15
85
2 Qmax
- 0.2 Qmax
10
SGM7004
0.67
0.04
10
0.6
100
6
-24
130
SGM7006
1.0
0.06
16.7
1
167
10
-39
215
1 Sensirion guarantees specifications of the SGM70xx module only.
2 slm: standard liter per minute; scmh: standard cubic meter per hour; conditions: T = 15°C and P = 1013 mbar.
3 Qstauration is defined as minimum / maximum linearized flow output value of the SGM70xx module.
4 Qoverflow is defined as overflow that does not damage the SGM70xx module.
5 Qreverse = maximum negative flow for which the initial accuracy applies as defined in Table 1.2 Physical specification.
6 Signal to noise ratio, 𝑆𝑁𝑅 = Mean Signal Amplitude
Std. Dev. Signal Amplitude
www.sensirion.com
Version 1.2 – July 2016
2/9