English
Language : 

FN2010B-20-08 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – General Purpose EMI Filter
2 EMC/EMI Products
Schaffner Group Datasheets 2014
Filter selection table
Filter*
FN 2010-1-..
FN 2010-3-..
FN 2010-6-..
FN 2010-10-..
FN 2010-12-..
FN 2010-16-..
FN 2010-20-..
FN 2010-30-08
FN 2010-60-24
Rated current
@ 40 °C (25 °C)
[A]
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
60 (69)
Leakage current**
@ 230 VAC/50 Hz
[mA]
0.74
0.74
0.74
0.74
0.74
0.74
0.74
0.87
0.87
Inductance
L
[mH]
12
2.5
1
0.8
0.7
0.7
0.6
0.7
1
Capacitance
Cx
Cy
[μF] [nF]
0.1
4.7
0.1
4.7
0.1
4.7
0.1
4.7
0.1
4.7
0.1
4.7
0.1
4.7
0.47
10
1.5
10
Resistance
R
[kΩ]
1000
1000
1000
1000
1000
1000
1000
1000
330
Input/Output
connections
Weight
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-08
-08
-24
[g]
65
65
65
85
85
140
210
470
1100
FN 2010A-1-..
FN 2010A-3-..
FN 2010A-6-..
FN 2010A-10-..
FN 2010A-12-..
FN 2010A-16-..
FN 2010A-20-..
FN 2010A-30-08
FN 2010A-60-24
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
60 (69)
0.074
0.074
0.074
0.074
0.074
0.074
0.074
0.074
0.074
12
0.1
0.47
2.5
0.1
0.47
1
0.1
0.47
0.8
0.1
0.47
0.7
0.1
0.47
0.7
0.1
0.47
0.6
0.1
0.47
0.7
0.47
0.47
1
1.5
0.47
1000
1000
1000
1000
1000
1000
1000
1000
330
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-08
-08
-24
65
65
65
85
85
140
210
470
1100
FN 2010B-1-..
FN 2010B-3-..
FN 2010B-6-..
FN 2010B-10-..
FN 2010B-12-..
FN 2010B-16-..
FN 2010B-20-..
FN 2010B-30-08
FN 2010B-60-24
1 (1.15)
3 (3.45)
6 (6.9)
10 (11.5)
12 (13.8)
16 (18.4)
20 (23)
30 (34.5)
60 (69)
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
12
0.1
2.5
0.1
1
0.1
0.8
0.1
0.7
0.1
0.7
0.1
0.6
0.1
0.7 0.47
1
1.5
1000
1000
1000
1000
1000
1000
1000
1000
330
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-06 -07
-08
-08
-24
** To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2010-30-08, FN 2010B-10-06).
** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
65
65
65
85
85
140
210
470
1100
Typical filter attenuation
Per CISPR 17; A = 50 Ω/50 Ω sym; B = 50 Ω/50 Ω asym; C = 0.1 Ω/100 Ω sym; D = 100 Ω/0.1 Ω sym
1 and 3 A types
6 to 12 A types
16 and 20 A types
30 and 60 A types