English
Language : 

FN2010B-20-08 Datasheet, PDF (1/5 Pages) List of Unclassifed Manufacturers – General Purpose EMI Filter
DATASHEET Single-Stage Filters FN 2010
General Purpose EMI Filter
Rated currents from 1 to 60 A
General purpose filtering performance
Optional medical versions (B type)
Optional safety versions (A type)
Approvals
Technical specifications
Maximum continuous operating voltage
Operating frequency
Rated currents
High potential test voltage
Temperature range (operation and storage)
Flammability corresponding to
Design corresponding to
MTBF @ 40°C/230V (Mil-HB-217F)
250 VAC, 50/60 Hz
dc to 400 Hz
1 to 60 A @ 40 °C max.
P –> PE 2000 VAC for 2 sec
P –> N 1100 VDC for 2 sec (30 and 60 A types)
P –> N 760 VAC for 2 sec (1 to 20 A types)
P –> PE 2500 VAC for 2 sec (B types)
-25 °C to +100 °C (25/100/21)
UL 94 V-2 or better
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
1,250,000 hours
3,200,000 hours (B types)
Features and benefits
FN 2010 filters are designed for easy and fast chassis
mounting
FN 2010 filters are also available as B versions
without Y-capacitors for medical applications as
well as A version with low capacitance for safety
critical applications with necessity for low leakage
currents
All filters provide a general purpose conducted
attenuation performance, based on chokes with
high saturation resistance and excellent thermal
behavior
FN 2010 filters can be used to cover a broad range of
usage and they offer a good size/amperage ratio
FN 2010 filters are also available as two-stage filters
(FN 2060, FN 2070 series) for more noisy
environment
Various terminal options allow you to select the
desired connection style
Typical applications
Electrical and electronic equipment
Consumer goods
Household equipment
Medical equipment
Office automation equipment
Datacom equipment
Typical electrical schematic