English
Language : 

205-P Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – 3 1/2 DIGIT MINI-SIZE PROCESS METER
AVAILABLE MODELS
DESCRIPTION
Field selectable/scalable for 4-20 mA, 0-199.9 mV dc,
1-5 V dc, 0-10 V dc, 0-100 V dc input
205-P with sensor excitation output
Field selectable for ranges ±1999.9 mV, ±1.999 V,
±19.999 V, ±100.0 V
PART #
205-P
205-E
205-A
ADD-ON OPTIONS
230 V ac Input Power
100 V ac Input Power
24 V ac Input Power (not CE approved)
5 V dc (for 205-A and 205-P only)
7-32 V dc (for 205-A and 205-P only)
Green LED display (instead of Red)
25 x 75 mm bezel adaptor
3/64 DIN to 1/8 DIN bezel adaptor
Ordering Example: 205-P-C1 (205-P unit w/ 230 Vac)
PART #
Add suffix "-C1"
Add suffix "-C5"
Add suffix "-C8"
Add suffix "-C3"
Add suffix "-C2"
Add suffix "-G"
Add suffix "TP2"
Add suffix "TP3"
Return Requests/Inquiries
Direct all warranty and repair requests/inquiries to the NEWPORT Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO NEWPORT, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM NEWPORT’S CUSTOMER SERVICE DEPARTMENT
(IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on
the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent
breakage in transit.
FOR WARRANTY RETURNS, please have the
following information available BEFORE
contacting NEWPORT:
1. P.O. number under which the product was
PURCHASED,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
FOR NON-WARRANTY REPAIRS, consult
NEWPORT for current repair charges. Have the
following information available BEFORE
contacting NEWPORT:
1. P.O. number to cover the COST of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems
relative to the product.
NEWPORT’s policy is to make running changes, not model changes, whenever an improvement is possible. This
affords our customers the latest in technology and engineering.
NEWPORT is a registered trademark of NEWPORT Electronics, Inc.
© Copyright 2005 NEWPORT Electronics, Inc. All rights reserved.
This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium
or machine-readable form, in whole or in part, without prior written consent of NEWPORT Electronics, Inc.
Warranty/Disclaimer
NEWPORT Electronics, Inc. warrants this unit to be free of defects in materials and
workmanship for a period of one (1) year from the date of purchase. In addition to
NEWPORT’s standard warranty period, NEWPORT Electronics will extend the warranty
period for one (1) additional year if the warranty card enclosed with each instrument is
returned to NEWPORT.
If the unit should malfunction, it must be returned to the factory for evaluation.
NEWPORT’s Customer Service Department will issue an Authorized Return (AR)
number immediately upon phone or written request. Upon examination by NEWPORT, if
the unit is found to be defective it will be repaired or replaced at no charge.
NEWPORT’s WARRANTY does not apply to defects resulting from any action of the
purchaser, including but not limited to mishandling, improper interfacing, operation
outside of design limits, improper repair, or unauthorized modification. This WARRANTY
is VOID if the unit shows evidence of having been tampered with or shows evidence of
being damaged as a result of excessive corrosion; or current, heat, moisture or
vibration; improper specification; misapplication; misuse or other operating conditions
outside of NEWPORT’s control. Components which wear are not warranted, including
but not limited to contact points, fuses, and triacs.
NEWPORT is pleased to offer suggestions on the use of its various
products. However, NEWPORT neither assumes responsibility for any
omissions or errors nor assumes liability for any damages that result
from the use of its products in accordance with information provided
by NEWPORT, either verbal or written. NEWPORT warrants only that
the parts manufactured by it will be as specified and free of defects.
NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF
ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF
TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of
purchaser set forth herein are exclusive and the total liability of
NEWPORT with respect to this order, whether based on contract,
warranty, negligence, indemnification, strict liability or otherwise,
shall not exceed the purchase price of the component upon which
liability is based. In no event shall NEWPORT be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by NEWPORT is not intended to be used, nor shall it be
used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear
installation or activity; or (2) in medical applications or used on humans. Should any
Product(s) be used in or with any nuclear installation or activity, medical application, or
used on humans, or misused in any way, NEWPORT assumes no responsibility as set
forth in our basic WARRANTY / DISCLAIMER language, and additionally purchaser will
indemnify NEWPORT and hold NEWPORT harmless from any liability or damage
whatsoever arising out of the use of the Product(s) in such a manner.
SPECIFICATIONS
ANALOG INPUT / 205-E & 205-P
Range
Input resistance
Bias current
Maximum input
4-20 mA
13 Ω
50 pA
55 mA
0-0.2 V
1 MΩ
50 pA
250 Vp
1-5 V
1 MΩ
10 pA
250 Vp
0-10 V
1 MΩ
5 pA
250 Vp
0-100 V
1 MΩ
1 pA
250 Vp
ANALOG INPUT / 205-A
Range
Input resistance
Bias current
Maximum input
±199.9 mV
1 GΩ
50 pA
100 Vp
±1.999 V
1.1 MΩ
5 pA
100 Vp
±19.99 V
1.0 MΩ
1 pA
100 Vp
±100.0 V
1.0 MΩ
1 pA
100 Vp
NOISE REJECTION
NMR, sig hi to sig lo
CMR, sig lo to pwr gnd
CMV, sig lo to pwr gnd
CMV, sig lo to dig return
(205-A)
56 dB, 50/60 Hz
120 dB, DC to 60 Hz
Dielectric strength to 1500V transient
per 260 Volt RMS or DC working
voltage.
0 volts
ACCURACY AT 25°C / DISPLAY
Maximum error
±0.05% of reading ±1 count
Display range
±1999
Span adjustment (205-P & -E) 0-2000 counts
Span tempco
±0.02% of reading/°C
Zero adjustment (205-P & -E) -1500 to +500 counts with zero input
Zero tempco (205-P & -E) ±0.01% of offset ±0.2 counts/°C
Full-scale step response
1 second
Warmup
30 minutes
Reading rate
2.5 / second
Overrange indication
Three least-significant digits blank
POWER OPTIONS / 205-E
Voltage
Frequency
Power
“Voltage options” with same
power and frequency.
115/230 Vac ±15%
50-60Hz
3.5W max.
“-C5” 100Vac ±15% (36mA max.)
“-C8” 24Vac ±10% (145mA max.)
POWER OPTIONS / 205-P & 205-A
Voltage
115/230 Vac ±15%
Frequency
50-60Hz
Power
2.5W max.
“Voltage options” with same
power and frequency.
AC
“-C5” 100Vac ±15% (36mA max.)
“-C8” 24Vac ±10% (133mA max.)
DC*
“-C2” 7-32 Vdc (100mA max.)*
“-C3” 5 Vdc (75mA max.)*
* External Supply must meet safety Agency Approval for safety DC
output. (Equipment CLASS I/II, CAT I min., Double Insulation)
SPECIFICATIONS (continued)
REQUIRED EXTERNAL FUSE PROTECTION
24Vac
100/115Vac
230Vac
160mA, UL Slow-Blow or IEC 127-2/111 Time-lag
40mA, UL Slow-Blow or IEC 127-2/111 Time-lag
20mA, UL Slow-Blow or IEC 127-2/111 Time-lag
ELECTRICAL SAFETY CLASSIFICATION
Installation Category
Pollution Degree
Class of Equipment
CAT I
2
I
per EN61010-1
per EN61010-1
per EN61010-1
TRANSMITTER EXCITATION SUPPLY / 205-E
Output voltage
Output current, max
Line regulation
Load regulation
Tempco
Ripple at 50/60 Hz
Selected for 10 or 24 V dc
30 mA @ 10 V, 20 mA @ 24 V
±0.01% / V of ac power
±0.5%
±0.02% / °C
±0.01%
DISPLAY
Type
Height
Symbols
Overrange Indication
31/2 digit, 7-segment, red or green LED
14.2 mm (0.56 in.)
-1.8.8.8
Three least-significant digits blank
ENVIRONMENTAL
Operating temperature
205-E
Operating temperature
205-P & 205-A
Storage temperature
Relative humidity
0°C to 50°C (32°F to 122°F)
0°C to 60°C (32°F to 140°F)
-40°C to +85°C (-40°F to 185°F)
95% at 40ºC (104°F) (non-condensing)
MECHANICAL
Case type
Bezel
Panel cutout 3/64 DIN
Panel Thickness
Depth behind bezel,
with connector
Weight
Case material
3/64 DIN (2472-100)
24 x 72 mm (0.94 x 2.83 in)
22.2 x 68 mm (0.87 x 2.68 in)
0.8 mm (0.03 in) min.
6.4 mm (0.25 in) max.
120 mm (4.72 in)
200 g (7 oz)
94V-1 UL-rated thermoplastic
It is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that
apply. NEWPORT is constantly pursuing certification of its products to the European New
Approach Directives. NEWPORT will add the CE mark to every appropriate device upon
certification.
The information contained in this document is believed to be correct but NEWPORT
Electronics, Inc. accepts no liability for any errors it contains, and reserves the right to alter
specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient
connected applications.
Caution, risk of danger. This device is marked with the international caution
symbol. It is important to read the Setup Guide before installing or commissioning
this device as it contains important information relating to safety and EMC.
MODEL 205-P, 205-E
and 205-A
3 1/2 DIGIT MINI-SIZE PROCESS METER (205-P)
PROCESS WITH ISOLATED EXCITATION (205-E)
DC VOLTAGE INPUT (205-A)
For immediate technical or application assistance please call:
Newport Electronics, Inc.
2229 South Yale Street • Santa Ana, CA • 92704 • U.S.A.
TEL: (714) 540-4914 • FAX: (203) 968-7311
Toll Free: 1-800-639-7678 • www.newportUS.com • e-mail:info@newportUS.com
ISO 9001 Certified
Newport Technologies, Inc.
976 Bergar • Laval (Quebec) • H7L 5A1 • Canada
TEL: (514) 335-3183 • FAX: (514) 856-6886
Toll Free: 1-800-639-7678 • www.newport.ca • e-mail:info@newport.ca
Newport Electronics, Ltd.
One Omega Drive • River Bend Technology Centre
Northbank, Irlam • Manchester M44 5BD • United Kingdom
Tel: +44 161 777 6611 • FAX: +44 161 777 6622
Toll Free: 0800 488 488 • www.newportuk.co.uk • e-mail:sales@newportuk.co.uk
Newport Electronics B.V.
Postbus 8034 • 1180 LA Amstelveen • The Netherlands
TEL: +31 20 3472121 • FAX: +31 20 6434643
Toll Free: 0800 0993344 • www.newport.nl • e-mail: info@newport.nl
Newport Electronics spol s.r.o.
Frystatska 184, 733 01 Karviná • Czech Republic
TEL: +420 59 6311899 • FAX: +420 59 6311114
Toll Free: 0800-1-66342 • www.newport.cz • e-mail: info@newport.cz
Newport Electronics GmbH
Daimlerstrasse 26 • D-75392 Deckenpfronn • Germany
TEL: 49 7056 9398-0 • FAX: 49 7056 9398-29
Toll Free: 0800 / 6397678 • www.newport.de • e-mail: sales@newport.de
Newport Electronique S.A.R.L.
11, rue Jacques Cartier • 78280 Guyancourt • France
TEL: +33 1 61 37 29 00 • FAX: +33 1 30 57 54 27
Toll Free: 0800 466 342 • www.newport.fr • e-mail: sales@newport.fr
Mexico and Latin America
FAX: 001 (203) 359-7807
En Español: 001 (203) 359-7803
10888ML-03 H/0305