Protection Classifications
I.P. Ingress Protection Classifications to DIN VDE 0470/EN 60529*
The protection classification offered by an enclosure is shown by the letters IP Ingress Protection, and two digits. The first digit
indicates two factors (protection for persons and equipment). The second digit indicates only one factor, protection against
water.
Similarly, changes in temperature, as may occur, for example, in the open air, are not taken into account. Such changes in
temperature may cause a loss of pressure in the enclosure, and dampness may be absorbed through the seal area.
Rose+Bopla can supply pressure compensation elements for this purpose.
First digit: Protection for persons and equipment
Persons
Digit
Brief Description
Definition
Equipment
Brief Description
Definition
0
Not protected
–
Not protected
–
Protection against the
A round body, 50mm in
1
back of the
hand touching
diameter, must be at a
sufficient distance from
dangerous parts
dangerous parts
Protection against a
solid foreign body of
50mm or more
in diameter
2
Protection against a
finger touching
dangerous parts
The test finger, jointed,
12mm in diameter and
80mm long, must be at a
sufficient distance from
dangerous parts
Protection against a
solid foreign body of
12.5mm or more
in diameter
3
Protection against
a tool touching
dangerous parts
A body, 2.5mm in
diameter, must not be
able to penetrate
Protection against a
solid foreign body of
2.5mm or more
in diameter
4
Protection against
a wire touching
dangerous parts
A body, 1.0mm in
diameter, must not be
able to penetrate
Protection against a
solid foreign body of
1.0mm or more
in diameter
Protection against
A body, 1.0mm in
5
a wire touching
diameter, must not be
Protection against dust
dangerous parts
able to penetrate
Protection against
A body, 1.0mm in
6
a wire touching
dangerous parts
diameter, must not be
able to penetrate
Sealed against dust
1)Dust must not penetrate in sufficient quantities to prevent the equipment from operating satisfactorily, or to impair safety.
A round body, 50mm
in diameter, must
not fully penetrate
A round body, 12.5mm
in diameter, must
not penetrate at all
A round body, 2.5mm
in diameter, must
not penetrate at all
A round body, 1.0mm
in diameter, must not
penetrate at all
No dust penetration
No dust penetration
Important note:The protection classifications given for the enclosures refer to unmachined enclosures as supplied. In the case of protection against water in particular
(second digit), the test conditions will be met if during the given time for the experiment no water has penetrated, or not in harmful quantities. As the tests to show
protection classifications take no account of ageing, the maintenance of the protection classification throughout the lifetime of the equipment in not guaranteed.
*We assume no liability for quoted standards.
158