4. Functional Specification
4.1 Commands
Refer to the Technical Manual for the SSD1351
Doc. No: SAS1-0D038-A
4.2 Power down and Power up Sequence
To protect OEL panel and extend the panel life time, the driver IC power up/down routine should include
a delay period between high voltage and low voltage power sources during turn on/off. It gives the
OEL panel enough time to complete the action of charge and discharge before/after the operation.
4.2.1 Power up Sequence:
1. Power up VCI / VDDIO
2. Send Display off command
3. Initialization
4. Clear Screen
5. Power up VCC
6. Delay 200ms
(When VCC is stable)
7. Send Display on command
4.2.2 Power down Sequence:
1. Send Display off command
2. Power down VCC
3. Delay 100ms
(When VCC is reach 0 and panel is completely
discharges)
4. Power down VCI / VDDIO
VCC
VCI/VDDIO
VSS/Ground
VCC
VCI/VDDIO
VSS/Ground
VCI / VDDIO on
VCC on
Display on
Display off
VCC off
VCI / VDDIO off
Note 9:
1) Since an ESD protection circuit is connected between VCI, VDDIO and VCC inside the driver IC, VCC
becomes lower than VCI whenever VDD, VDDIO is ON and VCC is OFF.
2) VCC should be kept float (disable) when it is OFF.
3) Power Pins (VDD, VDDIO, VCC) can never be pulled to ground under any circumstance.
4) VCI, VDDIO should not be power down before VCC power down.
4.3 Reset Circuit
When RES# input is low, the chip is initialized with the following status:
1. Display is OFF
2. 128(RGB)×128 Display Mode
3. Normal segment and display data column and row address mapping (SEG0 mapped to column
address 00h and COM0 mapped to row address 00h)
4. Display start line is set at display RAM address 0
5. Column address counter is set at 0
6. Normal scan direction of the COM outputs
7. Command A2h, B1h, B3h, BBh, BEh are locked by command FDh