Absolute Maximum Ratings
Table 5: Maximum Current and Reverse Voltage Ratings
CCT [2]
(Kelvin)
2700K
3000K
3500K
4000K
5000K
5600K
Part Number [1]
BXRA-27E3500-F-03
BXRA-27G3500-F-03
BXRA-27E4000-H-03
BXRA-27G4000-H-03
BXRA-27E7000-J-03
BXRA-27G7000-J-03
BXRA-30E3500-F-03
BXRA-30G3500-F-03
BXRA-30E4000-H-03
BXRA-30G4000-H-03
BXRA-30E7000-J-03
BXRA-30G7000-J-03
BXRA-35E3500-F-03
BXRA-35E4000-H-03
BXRA-35E7000-J-03
BXRA-40E4000-F-03
BXRA-40E4500-H-03
BXRA-40E7500-J-03
BXRA-50C4500-F-xx
BXRA-50C5300-H-xx
BXRA-50C9000-J-xx
BXRA-56C4500-F-xx
BXRA-56C5300-H-xx
BXRA-56C9000-J-xx
DC Forward Current for
LM-80 (mA) [4,5,6]
Maximum Peak
Pulsed Current
(mA) [14, 16]
Maximum Reverse
Voltage
(Vr) [15]
2100
2100
2800
2800
3500
3500
2100
2100
2800
2800
3500
3500
2100
2800
3500
2100
2800
3500
2100
2800
3500
2100
2800
3500
3000
-30
3000
-30
4000
-40
4000
-40
5000
-50
5000
-50
3000
-30
3000
-30
4000
-40
4000
-40
5000
-50
5000
-50
3000
-30
4000
-40
5000
-50
3000
-30
4000
-40
5000
-50
3000
-30
4000
-40
5000
-50
3000
-30
4000
-40
5000
-50
Notes for Table 5:
14. Bridgelux recommends a maximum duty cycle of 10% when operating LED Arrays at the maximum
peak pulsed current specified.
15. Light emitting diodes are not designed to be driven in reverse voltage.
16. Maximum peak pulsed currents are values at which the LED Array can be driven without catastrophic
failures.
17. DC Forward Current for LM-80 are the maximum drive currents for which LM-80 data is currently
available
18. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature
conditions used for LM-80 testing as included in the applicable LM-80 test report for these arrays.
19. Arrays can be driven at higher currents but lumen maintenance may be reduced
Bridgelux RS Array Series Product Data Sheet DS25 (8/30/2013 rev3)
Page 12 of 28