70053K Datasheet, PDF (12/28 Pages) List of Unclassifed Manufacturers – THE ADVANTAGES AND BENEFITS OF USING AMVECO TOROIDAL TRANSFORMERS
REFERENCE GUIDE FOR PHYSICAL SIZE AND LOSS DATA OF CUSTOM
DESIGNED TOROIDAL TRANSFORMERS UP TO 12 KVA
10"
10"
1 - 2.5"
Nominal
Power
( VA)
50-60 Hz
60Hz
15 18
30 36
50 60
80 95
120 145
160 190
225 270
300 360
400 480
500 600
625 750
800 960
990 1200
1100 1320
1300 1560
1600 1920
1900 2280
2200 2640
2500 3000
2800 3360
3200 3840
3700 4440
4400 5280
5000 6000
6300 7560
8000 9600
10000 12000
Copper
Losses(2)
(W)
3.0
5.8
8.6
12.0
16.0
19.0
20.0
22.0
27.0
31.0
36.0
45.0
45.0
45.0
60.0
62.0
65.0
73.0
79.0
89.0
91.0
93.0
112.0
112.0
130.0
140.0
140.0
Core
Losses
(W)
0.20
0.25
0.45
0.60
0.90
1.20
1.40
1.70
2.00
2.40
3.10
3.80
4.70
6.50
5.70
7.10
8.50
8.10
9.70
11.00
11.00
15.00
17.00
20.00
27.00
28.00
39.00
A
B
DISK MOUNTING
Dimensions
A
B
inch
inch
(mm)
(mm)
Weight
lb
(kg )
2.5 (64)
3.0 (76)
3.2 (81)
3.9 (99)
3.9 (99)
4.5 (114)
4.5 (114)
4.6 (117)
5.4 (137)
5.4 (137)
5.5 (140)
6.4 (163)
6.4 (163)
6.4 (163)
8.0 (203)
8.0 (203)
8.0 (203)
8.9 (226)
8.9 (226)
9.8 (249)
9.8 (249)
9.8 (249)
11.2 (284)
11.2 (284)
12.4 (315)
13.4 (340)
13.4 (340)
1.3 (33)
1.5 (38)
1.4 (36)
1.5 (38)
1.9 (48)
1.7 (43)
2.0 (51)
2.6 (66)
2.0 (51)
2.4 (61)
3.2 (81)
2.7 (69)
3.0 (76)
3.3 (84)
2.6 (66)
3.0 (76)
3.4 (86)
3.3 (84)
3.5 (89)
3.1 (79)
3.5 (89)
3.9 (99)
4.3 (109)
4.7 (119)
4.7 (119)
4.7 (119)
5.9 (150)
0.7 (0.3)
1.1 (0.5)
1.6 (0.7)
2.2 (1.0)
3.0 (1.4)
3.8 (1.7)
4.9 (2.2)
5.7 (2.6)
6.5 (3.0)
8.0 (3.6)
9.5 (4.3)
12.3 (5.6)
16.0 (7.3)
17.0 (7.7)
20.0 (9.1)
23.0 (10.4)
26.0 (11.8)
29.0 (13.2)
33.0 (15.0)
35.0 (15.9)
42.0 (19.1)
46.0 (20.9)
53.0 (24.0)
62.0 (28.1)
76.0 (34.5)
88.0 (39.9)
120.0 (54.4)
A
B
FLANGE MOUNTING
Dimensions
A
B
Weight
inch
inch
lb
(mm)
(mm)
(kg )
N/A
N/A
N/A
N/A
N/A
N/A
5.7 (145)
5.7 (145)
5.7 (145)
6.9 (175)
6.9 (175)
6.9 (175)
8.3 (211)
8.3 (211)
8.3 (211)
9.3 (236)
9.3 (236)
10.2 (259)
10.2 (259)
10.2 (259)
11.6 (295)
11.6 (295)
13.8 (351)
13.8 (351)
13.8 (351)
3.3 (84)
3.7 (94)
4.2 (107)
3.9 (99)
4.3 (109)
4.6 (117)
3.9 (99)
4.3 (109)
4.7 (119)
5.1 (130)
5.3 (135)
4.9 (124)
5.3 (135)
5.7 (145)
6.1 (155)
6.5 (165)
6.5 (165)
6.5 (165)
7.7 (196)
8.1 (3.7)
9.6 (4.4)
11.1 (5.0)
14.6 (6.6)
18.3 (8.3)
19.3 (8.8)
23.0 (10.4)
26.0 (11.8)
29.0 (13.2)
33.5 (15.2)
37.5 (17.0)
41.0 (18.6)
48.0 (21.8)
52.0 (23.6)
60.0 (27.2)
69.0 (31.3)
89.0 (40.4)
101.0 (45.8)
133.0 (60.3)
The values given are typical values. (2) Copper losses at 25˚C ambient temperature and full load.
Over 95% of our sales are custom designs. Because they require no elab-
orate production tools and are individually wound, toroidal transformers
are particularly well suited to custom designs.
Take advantage of our custom design service at no obligation.
Our interactive computer design capabilities enable us to optimize
design’s for either AC or DC loads.
• Quick response to Requests for Quotations
• Rapid delivery of prototypes
• Pre-certified by electrical safety agencies: UL and CSA
• Variety of mounting arrangements
• Lifetime Warranty
11
AMVECO Magnetics, Inc. • 10401 Westoffice Dr. • Houston, TX 77042 • (800) 527-7042 • (713) 977-2500 • Fax: (713) 977-5031 • Email: sales@amveco.com • www.amveco.com