Crimping of the Shielding Clamp
1 After completion of the soldering operations
carefully remove (holding on the locking collar)
the body/insulator assembly from the solder
termination fixture.
Soldered joints
Note
Exercise caution not to damage or deform the
solder joints.
2
Wires
Shielding mesh
Cable outer jacket
Cable outer jacket
Copper tape
2 Wrap the folded over shielding mesh with 5 to
6 mm wide copper tape to assure that it will
not become loose.
Apply the copper tape so that the shielding
mesh does not protrude from under it.
Copper tape 5 to 6mm
Note
After wrapping the copper tape, the tape
should overlap itself by 2 mm max.
3
Ground clamp
Copper tape
Cable outer jacket
1±0.5mm
Copper tape
Cable outer jacket
3 Insert the “U” shaped shielding clamp over the
copper tape as shown on the illustration.
It is critical that the overlap of the copper tape
is located inside the shielding clamp as shown
on the illustration.
Wires
Shielding mesh
Overlap of the copper tape
Shielding clamp
Note
When the end of the copper tape wrapping is
positioned at the open side of the ground
fitting, the end portion of the copper tape
wrapping will no longer be covered by the
ground fitting when the ground fitting is
crimped.
4
4 Using commercially available pliers bend the
open ends of the shielding clamp as illustrated,
Commercially
available pliers
assuring that it stays in place. The dimension
of E. between opposing edges of the shielding
clamp is necessary to assure correct final
E
crimp.
Shielding clamp
Overlap of the copper tape
Table 5
Shell size
-'
-'
-'
&
NNNBY
NNNBY
11