English
Language : 

CLS551 Datasheet, PDF (3/7 Pages) List of Unclassifed Manufacturers – CCD Linescan controller sensor
φOsc Timing
φOSC
tf
tr
tl
th
Item
φOSC pulse Duty *1
φOSC pulse rise / fall time
φOSC frequency
*1 100 x th / (tl + th )
Symbol
-
tr, tf
-
Min. Typ. Max. Unit
-
50
-
%
0
10
20
ns
-
10 10 MHz
Exposure timer control Note: For timing details
see t16, page 4
ts2 ts1 ts0
111
110
101
100
011
010
000
exposure time
2088 τ
4096 τ
8192 τ
16384 τ
32768 τ
65536 τ
extern
Note) τ is the period of φCLK (τ = 200 ns at 5 MHz).
Pixelclock control
ps2 ps1 ps0
φCLK
(at 10 MHz φCLK)
111
110
101
100
1/2 φOsc
1/4 φOsc
1/8 φOsc
1/16 φOsc
( 5 MHz)
( 2.5 MHz)
( 125 KHz)
( 62.5 KHz)
www.khs-instruments.com C551_01 Rev 1.01 / 06.2001 Specifications are subject to change without