UTI760A Datasheet, PDF (9/48 Pages) List of Unclassifed Manufacturers – UTI760A RTS Remote Terminal for Stores | |||
|
◁ |
1.5 MIL-STD-1760A Subaddress and Mode Code Deï¬nitions
Table 1. Subaddress and Mode Code Deï¬nitions Per MIL-STD-1760A Notice I
Subaddress Field
Binary (Decimal)
00000 (00)
00001 (01)
00010 (02)
00011 (03)
00100 (04)
00101 (05)
00110 (06)
00111 (07)
01000 (08)
01001 (09)
01010 (10)
01011 (11)
01100 (12)
01101 (13)
01110 (14)
01111 (15)
10000 (16)
10001 (17)
10010 (18)
10011 (19)
10100 (20)
10101 (21)
10110 (22)
10111 (23)
11000 (24)
11001 (25)
11010 (26)
11011 (27)
11100 (28)
11101 (29)
11110 (30)
11111 (31)
Message Format
Receive
Transmit
B.40.1.1.3 1
Reserved B.40.2.1 2
B.40.1.1.3
Store Description
User Deï¬ned
User Deï¬ned
Reserved
Reserved
User Deï¬ned
User Deï¬ned
Reserved
Reserved
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
Reserved
Reserved
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
Reserved
Reserved
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
Reserved
Reserved
Reserved
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
Reserved
Reserved
User Deï¬ned
User Deï¬ned
Reserved
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
Reserved
Reserved
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
User Deï¬ned
B.40.1.1.3
B.40.1.1.3
Description
Mode Code Indicator
Nuclear Weapon
Nuclear Weapon
Mode Code Indicator
Notes:
1. Refer to section B.40.1.1.3 of the MIL-STD-1760A speciï¬cation for deï¬nition.
2. Refer to section B.40.2.1 of the MIL-STD-1760A speciï¬cation for deï¬nition.
3. Reserved subaddresses illegalized; Message Error bit and pin set; SW transmitted.
RTS-9
|
▷ |