MLX90614 Datasheet, PDF (7/40 Pages) List of Unclassifed Manufacturers – Single and Dual Zone
MLX90614 family
Single and Dual Zone
Infra Red Thermometer in TO-39
Parameter
Symbol
Test Conditions
Min
Typ Max Units
Input high voltage
Input high voltage
Input low voltage
Input low voltage
Output low voltage
SMBus compatible 2-wire interface2
VIH
1.8
2
2.2
V
VIH(Ta,V)
Over temperature and supply
1.6
2.4
V
VIL
0.7
1.0
1.3
V
VIL(Ta,V)
Over temperature and supply
0.5
1.5
V
SDA pin in open drain mode,
VOL
over temperature and supply,
Isink = 2mA
0.2
V
SCL leakage
SDA leakage
SCL capacitance
SDA capacitance
Slave address
SMBus Request
ISCL,leak
ISDA,leak
CSCL
CSDA
SA
tREQ
VSCL=4V, Ta=+85°C
VSDA=4V, Ta=+85°C
Factory default
SCL low
5Ah
1.024
30
uA
0.3
uA
10
pF
10
pF
hex
ms
Timeout, low
Timeout,L
SCL low
30
ms
Timeout, high
Timeout,H
SCL high
50
us
Acknowledge setup time Tsuac(MD) 8-th SCL falling edge, Master
0.5
1.5
us
Acknowledge hold time
Thdac(MD) 9-th SCL falling edge, Master
1.5
2.5
us
Acknowledge setup time Tsuac(SD) 8-th SCL falling edge, Slave
2.5
us
Acknowledge hold time
Thdac(SD) 9-th SCL falling edge, Slave
1.5
us
EEPROM
Data retention
Ta = +85°C
10
years
Erase/write cycles
Ta = +25°C
100,000
Times
Erase/write cycles
Ta = +125°C
10,000
Times
Erase cell time
Terase
5
ms
Write cell time
Twrite
5
ms
Notes: All the communication and refresh rate timings are given for the nominal calibrated HFO frequency and will vary
with this frequency’s variations.
1. All PWM timing specifications are given for single PWM output (factory default for MLX90614xAx). For the extended
PWM output (factory default for the MLX90614xBx) each period has twice the timing specifications (refer to the PWM
detailed description section). With large capacitive load lower PWM frequency is recommended. Thermal relay output
(when configured) has the PWM DC specification and can be programmed as push-pull, or NMOS open drain. PWM is
free-running, power-up factory default is SMBus, refer to 7.6, “Switching between PWM and SMBus communication” for
details..
2. For SMBus compatible interface on 12V application refer to Application information section. SMBus compatible
interface is described in details in the SMBus detailed description section. Maximum number of MLX90614xxx devices on
one bus is 127, higher pullup currents are recommended for higher number of devices, faster bus data transfer rates, and
increased reactive loading of the bus.
MLX90614xxx is always a slave device on the bus. MLX90614xxx can work in both low-power and high-power SMBus
communication.
All voltages are referred to the Vss (ground) unless otherwise noted.
Power saving mode is not available on the 5V version (MLX90614Axx).
3901090614
Rev 003
Page 7 of 40
Data Sheet
03/Oct/2007