7 Electrical Specifications
7.1 MLX90614Axx
All parameters are preliminary for TA = 25 ˚C, VDD =5V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ
Max Units
External supply
Supply current
Supply current
(programming)
Supplies
VDD
4.5
5
5.5
V
IDD
No load
1
2
mA
IDDpr
No load, erase/write EEPROM
operations
1.5
2.5
mA
Zener voltage
Vz
Iz = 75…400 uA
5.6
5.75
5.8
V
Zener voltage
POR level
Vz(Ta)
Iz=70…400uA, full temperature
range
5.15
5.75
6.24
V
Power On Reset
VPOR
Power-up, power-down and
brown-out
2.7
3.0
3.3
V
VDD rise time
TPOR
Ensure POR signal
3
ms
Output valid (result in RAM)
Tvalid
After POR
Pulse width modulation1
0.15
s
PWM resolution
PWMres
Data band
10
bit
PWM output period
PWM period stability
Output high Level
Output low Level
Output drive current
Output sink current
Output settling time
Output settling time
PWMT,def
Factory default, internal oscillator
factory calibrated
1.024
ms
Internal oscillator factory
dPWMT
calibrated, over the entire
operation range and supply
-4
voltage
+4
%
PWMHI
Isource = 2 mA
VDD-0.2
V
PWMLO
IdrivePWM
IsinkPWM
Tset
Isink = 2 mA
Vout,H = VDD - 0.8V
Vout,L = 0.8V
100 pF capacitive load, full
operating Ta range
VSS+0.2 V
7
mA
13.5
mA
500
ns
220 Ohm in series with 47nF load
TsetRC
on the wire, full Ta operating
20
range
50
us
3901090614
Rev 003
Page 6 of 40