TC164 Datasheet, PDF (5/7 Pages) List of Unclassifed Manufacturers – CHIP RESISTORS ARRAY | |||
|
◁ |
5
Chip Resistor Surface Mount TC SERIES 164
7
TYPE
Temperature
Coefficient of
Resistance
(T.C.R.)
TEST METHOD
Measure resistance at
+25°C or specified room
temperature as R1, then
measure at â55°C or
+155°C respectively as R2.
Determine the
temperature coefficient of
resistance from the
following formula:
Formula
R2âR1
T.C.R. = ------------------------- Ã106 (ppm/°C)
R1(t2ât1)
Where
t1=+25°C or specified room temperature
t2=â55°C or +155°C test temperature
R1=resistance at reference temperature in ohms
R2=resistance at test temperature in ohms
ACCEPTANCE STANDARD
Refer to table 2
Thermal
Shock
At â55±3°C for 2 minutes and at +155±2°C for 2 minutes as one cycle. After 5
cycles, the specimen shall be stabilized at room temp.
Measure the resistance to determine ÎR/R(%) after one more hour.
±(1.0%+0.05â¦)
Low
Temperature
Operation
Place the specimen in a test chamber maintained at â65 (+0/â5)°C. After one hour
stabilization at this temperature, full rated working voltage shall be applied for 45
(+5/â0) minutes. Have15 (+5/â0 ) minutes after remove the voltage, the specimen
shall be removed from the chamber and stabilized at room temperature for 24 hrs.
Measure the resistance to determine ÎR/R(%).
±(1.0%+0.05â¦)
No visible damage
Short
Time
Overload
Apply 2.5 times of rated voltage but not exceeding the maximum overload voltage
for 5 seconds. Have the specimen stabilized at room temperature for 30 minutes
minimum.
Measure the resistance to determine ÎR/R(%).
±(2.0%+0.05â¦)
No visible damage
Insulation
Resistance
Place the specimen in the jig and apply a rated
continues overload voltage (R.C.O.V) for one
minute as shown.
Measure the insulation resistance.
Type
Voltage (DC)
TC164
100V
â¥10,000Mâ¦
Dielectric
Withstand
Voltage
Place the specimen in the jig and apply a
specified value continuous overload voltage as
shown for one minute.
Type
Voltage (AC)
TC164
100Vrms
Breakdown voltage>
specification and without
open/short
Resistance
To Soldering
Heat
Immerse the specimen in the solder pot at 260±5°C. for 10±1 seconds. Have the
specimen stabilized at room temperature for 30 minutes minimum.
Measure the resistance to determine ÎR/R(%).
±(1.0%+0.05â¦)
No visible damage
Mar. 24, 2004 V.4
www.yageo.com
|
▷ |