SCA61T Series
1.6 SPI Interface Timing Specifications
Parameter
Terminal CSB, SCK
Time from CSB (10%)
to SCK (90%)
Time from SCK (10%)
to CSB (90%)
Terminal SCK
SCK low time
SCK high time
Terminal MOSI, SCK
Time from changing MOSI
(10%, 90%) to SCK (90%).
Data setup time
Time from SCK (90%) to
changing MOSI (10%,90%).
Data hold time
Terminal MISO, CSB
Time from CSB (10%) to stable
MISO (10%, 90%).
Time from CSB (90%) to high
impedance state of
MISO.
Terminal MISO, SCK
Time from SCK (10%) to stable
MISO (10%, 90%).
Terminal CSB
Time between SPI cycles, CSB at high
level (90%)
When using SPI commands RDAX, RDAY,
RWTR: Time between SPI cycles, CSB at
high level (90%)
Conditions
Load
capacitance at
MISO < 2 nF
Load
capacitance at
MISO < 2 nF
Load
capacitance at
MISO < 15 pF
Load
capacitance at
MISO < 15 pF
Load
capacitance at
MISO < 15 pF
Symbol Min. Typ. Max. Unit
TLS1
120
ns
TLS2
120
ns
TCL
1
µs
TCH
1
µs
TSET
30
ns
THOL
30
ns
TVAL1
10
TLZ
10
100 ns
100 ns
TVAL2
100 ns
TLH
15
µs
TLH 150
µs
CSB
SCK
MOSI
MISO
TLS1
TVAL1
TCH
TCL
THOL
MSB in
MSB out
TVAL2
DATA in
DATA out
TLS2
TLH
TSET
LSB in
TLZ
LSB out
Figure 2. Timing diagram for SPI communication
VTI Technologies Oy
www.vti.fi
Subject to changes
Doc. nr. 8261900
5/18
Rev.A