XHP Series
3.3V @ 30A, SINGLE OUTPUT DC/DC CONVERTERS
TECHNICAL NOTES
Trimming Output Voltages
UHP converters have a trim capability (pin 7) that allows users to adjust the
output voltage 5%. Adjustments can be accomplished via a trim pot, Figure 2,
or a single fixed resistor as shown in Figures 3 and 4. A single fixed resistor
can increase or decrease the output voltage depending on its connection.
Fixed resistors should have absolute TCR's less than 100ppm/°C to minimize
sensitivity to changes in temperature.
A single resistor connected from the Trim (pin 7) to the +Sense (pin 6), see
Figure 3, will increase the output voltage. A resistor connected from the Trim
(pin 7) to the –Sense (pin 8) will decrease the output voltage. See Figure 4.
Trim adjustments greater than +10%/–20% can have an adverse effect on the
converter's performance and are not recommended.
1 –INPUT
2
CASE
3 ON/OFF
CONTROL
4
+INPUT
5
+OUTPUT
6
+SENSE
7
TRIM
8
–SENSE
9
–OUTPUT
20kΩ
5-22
TURNS
LOAD
1 –INPUT
2
CASE
3 ON/OFF
CONTROL
4
+INPUT
5
+OUTPUT
6
+SENSE
7
TRIM
RTRIM DOWN
8
–SENSE
9
–OUTPUT
LOAD
Figure 4. Trim Connections To Decrease Output Voltages Using Fixed Resistors
Trim Up Equation
13.3(VO – 1.226)
RT UP (kΩ) =
VO – 3.3
–10.2
Trim Down Equation
16.31
RTDOWN (kΩ) = 3.3 – VO –10.2
Accuracy of adjustment is subject to tolerances or resistor values
and factory-adjusted output accuracy. VO = desired output voltage.
Figure 2. Trim Connections Using A Trim Pot
1 –INPUT
2
CASE
3 ON/OFF
CONTROL
4
+INPUT
5
+OUTPUT
6
+SENSE
7
TRIM
8
–SENSE
RTRIM UP
9
–OUTPUT
LOAD
Figure 3. Trim Connections To Increase Output Voltages Using Fixed Resistors
Output Current vs. Ambient Temperature
VIN = 48V, Air flow from output pins to input pins
30
25
150lfm
200lfm
20
400lfm
300lfm
15
10
NATURAL CONVECTION
5
0
28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 94 96 100
Ambient Temperature (˚C)
®
®
INNOVATION and EXCELLENCE
ISO 9001 REGISTERED
DS0492
2/01
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
Internet: www.datel.com Email: sales@datel.com
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444
DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01
DATEL GmbH München, Germany Tel: 89-544334-0
DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.
4