English
Language : 

SMI30 Datasheet, PDF (4/6 Pages) List of Unclassifed Manufacturers – Intrinsically Safe Sensors
CI3RC2 Current Amplifier Module
Hookup to Banner MAXI-AMP CI3RC2
Current Amplifier Module
SAFE AREA
(see the data sheet packed with the CI3RC2 for more information)
HAZARDOUS AREA
Hookup using two single-channel barriers
RELAY OUTPUT
5 AMP CONTACTS
AC
SUPPLY
105 to 130V ac
210 to 250V ac
INPUT:
≤10 MA. (OFF STATE)
≥20 MA. (ON STATE)
AUX.
INPUT
COMMON
CI3RC2
OPTO-COUPLER
OUTPUT: 20mA max.
IN +
V
-
I.S.
BARRIER
IN +
V
-
I.S.
BARRIERG
BUSBAR
G
EARTH GROUND
(less than 1Ω)
Hookup using one dual-channel barrier
RELAY OUTPUT
5 AMP CONTACTS
AC
SUPPLY
105 to 130V ac
210 to 250V ac
1
+ OUT
BROWN 2
-
3
BLUE
SMI30
Series
Emitter
BLACK
1
+ OUT
BROWN 2
3
-
BLUE
SMI30
Series
Receiver
BOTTOM VIEW OF SENSOR
(colors shown are for mating
cable model MBCC-312)
INPUT:
≤10 MA. (OFF STATE)
≥20 MA. (ON STATE)
AUX.
INPUT
COMMON
CI3RC2
OPTO-COUPLER
OUTPUT: 20mA max.
SAFE AREA
HAZARDOUS AREA
IN +
-
Dual Barrier + OUT
I.S.
-
BROWN
2
1
SMI Series
3 Emitter
BLUE
IN +
EARTH GROUND
(less than 1Ω)
BUSBAR
G
+ OUT
BROWN
BLACK
1
2
3
BLUE
SMI Series
Receiver
BOTTOM VIEW OF CABLE
CONNECTOR ON SENSOR
(colors shown are for mating
cable model MBCC-312)
MAXI-AMP™ CI3RC2 Module
Banner MAXI-AMP module model CI3RC2 (part number 36606)
is a self-contained module which converts the current output signal
of an SMI30 Series sensor to a trip point switch.
Both sensors of the opposed mode pair are wired to model CI3RC2
using the two-wire hookup, which requires the use of two single
channel or one dual channel intrinsic safety barrier(s). In this mode,
the SMI30 receiver sinks ≤10 milliamps in the "OFF" state and ≥20
milliamps in the "ON" state. The CI3RC2 senses this current change
and switches internal relays which are easily wired to most loads and/
or additional control circuitry.
Model CI3RC2 is powered by either 105-130 or 210-250V ac. The
CI3RC2 supplies power to operate both the emitter and receiver.
Inputs are protected against short circuits. Built-in circuit diagnos-
tics indicate an overload of either input by pulsing an LED status
light.
The CI3RC2 module has two isolated output switches. There is a 5
amp rated SPDT electromechanical relay, and a solid-state transistor
switch which may be used for logic-level interfaces.
SPECIFICATIONS, CI3RC2
SUPPLY VOLTAGE: 105 to 130 or 210 to 250V ac, 50/60 Hz (8VA).
OUTPUT CONFIGURATION:
SPDT electromechanical relay:
Contact rating: 250V ac max., 24V dc max., 5 amps max. (resistive load),
1/10 HP at 240V ac. Install transient suppressor (MOV) across contacts
that switch inductive loads.
Closure time: 10 milliseconds max.
Release time: 10milliseconds max.
Maximum switching speed: 20 operations/second.
Mechanical life: 20,000,000 operations
Solid-state dc relay: SPST optically-coupled transistor;
30V dc max., 20mA max.
Functional Schematic, CI3RC2
INPUTS:
Trip point for output "OFF": ≤10 milliamps
Trip point for output "ON": ≥20 milliamps
Trip point range for input overload indication: 30mA ≤ I ≤ 80mA.
INDICATOR LEDs: Status indicator for OUTPUT "ON" and INPUT
overload/short.
OPERATING TEMPERATURE: 0 to 50°C (32 to 122°F).
CONSTRUCTION: rugged NORYL® polyphenylene oxide (PPO™)
housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole base. Use RS-11
socket or equivalent.
4