English
Language : 

CHP0230-PM Datasheet, PDF (4/4 Pages) List of Unclassifed Manufacturers – 824 to 849 MHz 28.5 dBm, Cellular InGaP HBT Amplifier Module
CHP0230-PM
Product Specifications - July 2002
(4 of 4)
TM
Recommended Application Circuit
Note: This schematic represents the topology of the application cir-
cuit recommended by Celeritek.
Vcc
10 µF
1
RF IN
Vref
2
50Ω 3
T1
CHP0230-PM
6
5
220 pF
4
N/C
3.3 µF
RF OUT
50Ω
T1 line is important to ensure best bypassing. Optimum performance
is achieved through an electrical length of 20°min. at 835 MHz.
Evaluation Board Schematic
Board substrate:
ER = 4.60
Thickness = 0.031 in.
PCB Footprint (Minimum Pad Dimensions)
0.295 (7.50)
0.100 (2.55)
0.032 (0.80)
MIN. X6
0.240
(6.10)
0.015 (0.38) DIA.
VIA HOLE X21
0.054 (1.36) X4
0.060 (1.50) MIN.
0.015 (0.40)
RADIUS
X12
DIMENSIONS IN INCHES (mm)
DRAWING NOT TO SCALE
Physical Dimensions
Ordering Information
The CHP0230-PM is available in a surface mount 50 ohm matched module and devices are available in tube or tape and reel.
Part Number for Ordering
Package
CHP0230-PM-0000
PM6 surface mount power package in tube
CHP0230-PM-000T
PM6 surface mount power package in tape and reel
PB-CHP0230-PM
Evaluation Board with SMA connectors for CHP0230-PM
Celeritek reserves the right to make changes without further notice to any products herein. Celeritek makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does Celeritek assume any liability arising out of the application or use of any product or circuit, and specifically
disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters can and do vary in different applications. All operating
parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Celeritek does not convey any license under its patent
rights nor the rights of others. Celeritek products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body,
or other applications intended to support or sustain life, or for any other application in which the failure of the Celeritek product could create a situation where personal
injury or death may occur. Should Buyer purchase or use Celeritek products for any such unintended or unauthorized application, Buyer shall indemnify and hold Celeritek
and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out
of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Celeritek was negligent
regarding the design or manufacture of the part. Celeritek is a registered trademark of Celeritek, Inc. Celeritek, Inc. is an Equal Opportunity/Affirmative Action Employer.
3236 Scott Boulevard, Santa Clara, California 95054
Phone: (408) 986-5060
Fax: (408) 986-5095