English
Language : 

ADC8032A Datasheet, PDF (36/52 Pages) List of Unclassifed Manufacturers – Analog Composite to SDI Decoder
Bank C-6: Set Minimum Delay
Use the following steps to reset both the H Delay and V Delay values to 0 (zero).
1. Select Bank C, and rotate Function Select to position 6.
2. Reset all delays as required:
• Toggle Mode Select up to reset H Delay and V Delay to 0.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
6
+
Zero
MIN DEL ZERO
N/A
-
No action
Bank C- 7: Input Mode
The Input Mode function selects what type of video is being input. The choices are:
• Standard – standard
• VTR – input signals that do not have a stable timebase, such as from VTR’s or
VCR’s
When VTR is selected as the video Input Mode, an external reference is required to reclock the input
signal to the house clock. The external reference provides stable output timing.
Use the following steps to set the Input Mode:
1. Select Bank C, and rotate Function Select to position 7.
2. Select the desired Input mode according to the following table.
• Toggle Mode Select up to set VTR mode
• Toggle Mode Select down to set STANDARD mode.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
7
+ VTR mode
IN MODE
VTR
STAND
- STANDARD mode
STAND
Note
Note
A reference must be connected when in VTR Mode.
A reference must be connected when in VTR Mode. This
mode affects the Hotswitch Mode. Timebase error-prone
signals such as from a VCR will falsely trigger the hotswitch
detector. Thus, an Input Mode selection of VTR will force the
Hotswitch Mode to OFF.
4-18 • Using Banks
ADC-8032A User Manual (Iss. 04)