English
Language : 

ADC8032A Datasheet, PDF (20/52 Pages) List of Unclassifed Manufacturers – Analog Composite to SDI Decoder
1. No display - Adjustments are made using the Function Select and Mode Select
switches, without the assistance of the Heads-Up Display or the Comlink
Display. Results should be confirmed with test equipment suitable for
measuring the parameter being adjusted (such as a waveform monitor or vector
scope).
2. Heads-Up Display - Adjustments are made using Function Select and Mode
Select switches in conjunction with the Heads-Up Display. Ensure that the
Heads-Up Display is enabled (Bank A, Position 1). Note that the display is
superimposed over all ADC-8032A video outputs.
3. Terminal Display - Adjustments are made using Function Select and Mode
Select switches in conjunction with the Comlink Display. Ensure that the
Comlink port is properly connected to a PC. Refer to Chapter 8, “Comlink”
for instructions.
Note
Both the Heads-Up Display and the Comlink Display can be used
simultaneously.
Operating Conventions For Function Tables
The following rules apply to the function tables that are used throughout this section:
• The label “ + ” instructs you to toggle the Mode Select switch (SW2) up
momentarily.
• The label “ - ” instructs you to toggle the Mode Select switch (SW2) down
momentarily.
• The label “ + (h) ” instructs you to hold the Mode Select switch (SW2) up for one
second.
• The label “ - (h) ” instructs you to hold the Mode Select switch (SW2) down for one
second.
Selecting Banks
Function Select switch functionality is divided into three banks of functions. Use the following steps
to select Bank A, B or C as required.
1. Rotate Function Select (SW1) to position 0. Note that position 0 is always used to
select the bank, regardless of the bank that you are currently using.
2. Toggle Mode Select (SW2) up or down to choose the desired bank. Three positions
are available: Bank A, B or C.
3. The table below illustrates each switch function, along with the Heads-Up Display
label, the Status LED indication, and the default value. If you are not using a
display, be sure to verify your selection on the Status LED's.
Table 2. Switch and Bank Selection
Mode Select SW2
Heads-up Display Label Status LED Default Bank
+
A
B
-
C
BANK A
BANK B
BANK C
BANK A
A
BANK B
A
BANK C
A
4-2 • Using Banks
ADC-8032A User Manual (Iss. 04)