BC1601A Datasheet, PDF (33/33 Pages) List of Unclassifed Manufacturers – LCD MODULE SPECIFICATION
12-3.5.2 4-bit interface
Power on
Wait for more than 15 ms after VCC rises to 4.5 V
RS R/W DB7 DB6 DB5 DB4
000011
BF can not be checked before this instruction.
Function set ( Interface is 8 bits long. )
Wait for more than 4.1 ms
RS R/W DB7 DB6 DB5 DB4
000011
BF can not be checked before this instruction.
Function set ( Interface is 8 bits long. )
Wait for more than 100 µs
RS R/W DB7 DB6 DB5 DB4
000011
RS R/W DB7 DB6 DB5 DB4
00 0 0 10
0 0 0 0 10
0 0 NF * *
000000
00 1000
000000
000001
000000
0 0 0 0 I/D S
Initialization ends
4-Bit Ineterface
BF can not be checked before this instruction.
Function set ( Interface is 8 bits long. )
BF can be checked after the following instructions.
When BF is not checked , the waiting time between
instructions is longer than execution instruction time.
Function set ( Set interface to be 4 bits long. )
Interface is 8 bits in length.
Function set ( Interface is 4 bits long. Specify
the number of display lines and character font. )
The number of display lines and character font
can not be changed after this point.
Display off
Display clear
Entry mode set