English
Language : 

BC1601A Datasheet, PDF (18/33 Pages) List of Unclassifed Manufacturers – LCD MODULE SPECIFICATION
11. Reliability
Content of Reliability Test
Environmental Test
No. Test Item
Content of Test
Test Condition
Applicable
Standard
1
High Temperature
storage
Endurance test applying the high
storage temperature for a long time.
60
200hrs
——
2
Low Temperature
storage
Endurance test applying the high -20
storage temperature for a long time. 200hrs
——
3
High Temperature
Operation
Endurance test applying the electric
stress (Voltage & Current) and the
thermal stress to the element for a
long time.
50
200hrs
——
4
Low Temperature
Operation
Endurance test applying the electric
stress under low temperature for a
0
long time.
200hrs
——
5
High Temperature/
Humidity Storage
Endurance test applying the high
temperature and high humidity
storage for a long time.
60 ,90%RH
96hrs
——
Endurance test applying the electric
6
High Temperature/ stress (Voltage & Current) and
Humidity Operation temperature / humidity stress to the
40 ,90%RH
96hrs
element for a long time.
——
Endurance test applying the low and
high temperature cycle.
7 Temperature Cycle
-20
25
30min 5min
1 cycle
60
30min
-20 /60
10 cycles
——
Mechanical Test
8 Vibration test
10~22Hz 1.5mmp-p
Endurance test applying the vibration
during transportation and using.
22~500Hz
1.5G
Total 0.5hrs
——
Constructional and mechanical
50G Half sign
9 Shock test
endurance test applying the shock wave 11 msedc
during transportation.
3 times of each direction
——
10
Atmospheric
pressure test
Endurance test applying the
atmospheric pressure during
transportation by air.
115mbar
40hrs
——
Others
11
Static
electricity
test
Endurance test applying
stress to the terminal.
the
electric
VS=800V,RS=1.5k
CS=100pF
1 time
——
***Supply voltage for logic system=5V. Supply voltage for LCD system =Operating voltage at 25