Series HA60/HD60
25-125Amp ⢠600 Vac ⢠AC Output
CURRENT DERATING CURVES
25A
30
95
1ËC/W
25
100
3ËC/W 2ËC/W
20
15
110
10
NO HEATSINK
5
120
0
5 10 15 20 25 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
90A
120
90
.5ËC/W .2ËC/W
.4ËC/W 100
80
1ËC/W
110
40
120
0
20 40 60 80 0 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
50A
60
1ËC/W .5ËC/W 90
1.5ËC/W
40
100
2ËC/W
20
110
NO HEATSINK
120
0
10 20 30 40 50 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
125A
160
90
.4ËC/W
120
.5ËC/W
.2ËC/W
100
80
1ËC/W
110
40
120
0
30 60 90 120 0 20 40 60 80
Load Current [Arms]
Max Ambient Temp. [ËC]
© 2002 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.159
SERIES HA/HD60.
Rev. 031802
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 ⢠FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
|