English
Language : 

IP100ALF Datasheet, PDF (29/97 Pages) List of Unclassifed Manufacturers – Integrated 10/100 Ethernet MAC + PHY
BIT
BIT NAME
7
Collision Test
6..0 Reserved
IP100A LF
Preliminary Data Sheet
R/W
R/W
N/A
BIT DESCRIPTION
1 = Enable COL test. If Collision Test is a logic 1 and transmit
data is sent to the PHY, the IP100A LF PHY will assert the
collision signal within 512 bit times (where 1 bit time = 100ns
for 10Mbps operation and 1 bit time = 10ns for 100Mbps
operation). When transmit data is removed, the IP100A LF
PHY will deassert the collision signal within 4 bit times.
0 = Normal operation.
Reserved for future use.
11.1.2 Status Register
Class............................. PHY Registers
Access Method............. Accessed through PhyCtrl register
Register Address.......... 0x01
Default .......................... 0x7849
Width ............................ 16 bits
BIT
BIT NAME
15
100BASE-T4
14
13
12
11
10..7
6
5
100BASE-X Full
Duplex
100BASE-X Half
Duplex
10BASE-T Full
Duplex
10BASE-T Half
Duplex
Reserved
Preamble
Suppression
Auto-Negotiation
Complete
4
Remote Fault
R/W
R
R
R
R
R
N/A
R
R
R
BIT DESCRIPTION
1 = PHY 100BASE-T4 capable.
0 = PHY not 100BASE-T4 capable.
1 = PHY 100BASE-X Half Duplex capable.
0 = PHY not 100BASE-X Half Duplex capable.
1 = PHY 100BASE-X Half Duplex capable.
0 = PHY not 100BASE-X Half Duplex capable.
1 = PHY 10BASE-T Full Duplex capable.
0 = PHY not 10BASE-T Full Duplex capable.
1 = PHY 10BASE-T Half Duplex capable.
0 = PHY not 10BASE-T Half Duplex capable.
Reserved for future use.
1 = Management preamble may be suppressed.
0 = Management preamble required.
1 = Auto-Negotiation complete.
0 = Auto-Negotiation not complete.
If Auto-Negotiation Complete is a logic 1, the auto-negotiation
process is complete and the contents of the Auto-Negotiation Link
Partner Ability and Auto-Negotiation Expansion registers are
valid. If Auto-Negotiation Complete is a logic 0, the
Auto-Negotiation process is not complete, and the contents of the
Auto-Negotiation Link Partner Ability and Auto-Negotiation
Expansion registers are undefined. If the Auto-Negotiation bit of
the Control Register is a logic 0, then Auto-Negotiation Complete
is always a logic 0.
1 = Remote Fault detected.
0 = Remote Fault not detected.
If Remote Fault is a logic 1, the IP100A LF has detected a remote
fault condition. Remote Fault will remain a logic 1 until the remote
fault condition no longer exists, and Remote Fault is read by the
host system.
Copyright © 2004, IC Plus Corp.
29/97
March. 30, 2007
IP100A LF-DS-R17