11.0 Environment
The display module will meet the provision of this specification during operating condition or after storage or
shipment condition specified below. Operation at 10% beyond the specified range will not cause physical
damage to the unit.
11.1 Temperature and Humidity
11.1.1 Operating Conditions
The display module operates error free, when operated under the following conditions;
Temperature
0 0C to 50 0C
Relative Humidity
Wet Bulb Temperature
20% to 85%
39.0 0C
11.1.2 Shipping Conditions
The display module operates error free, after the following conditions;
Temperature
-20 0C to 60 0C
Relative Humidity
Wet Bulb Temperature
5% to 95%
39.0 0C
11.2 Atmospheric Pressure
The display assembly is capable of being operated without affecting its operations over the pressure range as
following specified:
Pressure
Maximum Pressure
1040 hPa
Minimum Pressure
601 hPa
Note: Non-operation altitude limit of this display module = 40,000 feet. = 12193 m.
Altitude
0 m = sea level
3658 m = 12,000 feet
11.3 Thermal Shock
The display module will not sustain damage after being subjected to 100 cycles of rapid temperature change. A
cycle of rapid temperature change consists of varying the temperature from -200C to 600C, and back again.
Thermal shock cycle
-20 0C for 30min
60 0C for 30min
Power is not applied during the test. After temperature cycling, the unit is placed in normal room ambient for at
least 4 hours before powering on.
(C) Copyright AU Optronics, Inc.
Feb. 2003 All Rights Reserved.
No Reproduction and Redistribution Allowed.
M150XN07
Ver0.1
21/28