9.7 RELIABILITY
MB-TFT-35-S4-S
Test Item
High Temperature Operation
Low Temperature Operation
High Temperature Storage
Low Temperature Storage
Humidity Test
Thermal Shock Test
Vibration Test (Packing)
Static Electricity
Test Conditions
70±3°C, t=96 hrs
-20±3°C, t=96 hrs
80±3°C, t=96 hrs
-30±3°C, t=96 hrs
40°C, Humidity 90%, 96 hrs
-30°C ~ 25°C ~ 80°C 30 min. 5 min.
30 min. (1 cycle)
Total 5 cycle
Sweep frequency:10~55~10
Hz/1min
Amplitude: 0.75mm
Test direction: X.Y.Z/3 axis
Duration: 30min/each axis
150pF 330 ohm +8kV, 10times air
discharge
Note
1,2
1,2
1,2
1,2
1,2
2
Note 1: Condensation of water is not permitted on the module.
Note 2: The module should be inspected after 1-hour storage in normal conditions
(15-35°C, 45-65%RH).
Definitions of life end point:
l Current drain should be smaller than the specific value.
l Function of the module should be maintained.
l Appearance and display quality should not have degraded noticeably.
l Contrast ratio should be greater than 50% of the initial value.
10 USE PRECAUTIONS
10.1 Handling precautions
1) The polarizing plate may break easily so be careful when handling it. Do
not touch, press or rub it with a hard-material tool like tweezers.
2) Do not touch the polarizing plate surface with bare hands so as not to
make it dirty. If the surface or other related part of the polarizing plate is dirty,
soak a soft cotton cloth or chamois leather in benzine and wipe off with it. Do
not use chemical liquids such as acetone, toluene and isopropyl alcohol.
Failure to do so may bring chemical reaction phenomena and deteriorations.
3) Remove any spit or water immediately. If it is left for hours, the suffered
part may deform or decolorize.