English
Language : 

T9AS1D12-12 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Low Cost 30 Amp PC Board or Panel Mount Relay
Ambient Temperature vs. Coil Voltage - 1 Watt Coil
Data below are average values and should be verified in application. Tests
were conducted within a 2' (.6 m) cube (still air); at nominal coil power @
25°C; with normally open contact loaded; and with 4' (1.22 m) long, #10
AWG load wires. P.C. board relays were mounted to a 30A, single side P.C.
board (6).
140
120
100
80
60
40
Sealed Relay, Vented (note 3);
20 Load Connections Via Q.C. Terminals,
PC Mount
0
60
80
100
120
140
160
Applied Continuous Coil Voltage (% of Rated Voltage)
0A
10A
20A
30A
180
140
120
100
80
60 Relay With Dust Cover,
Flange Mount
40
60
80
100
120
140
160
Applied Continuous Coil Voltage (% of Rated Voltage)
140
0A
10A
20A
30A
180
120
100
80
60
40
20 Sealed Relay, Vented (note 3)
PC Terminals For Coil & Contacts
0
60
80
100
120
140
160
Applied Continuous Coil Voltage (% of Rated Voltage)
0A
10A
20A
30A
180
Environmental Data
Storage Temperature Range: -55°C to 130°C.
Operating Temperature Range(1): -55°C to +85°C.
Vibration, Operational: 0.065" (1.65mm) max. excursions from 10-55 Hz.
with no contact opening >100µs.
Shock, Operational: 10g for 11 ms with no contact opening >100µs.
Shock, Mechanical: 100g.
Mechanical Data
Termination: Printed circuit and quick connect terminals (4).
Enclosures (all have 94V-0 flammability rating):
T9AP: Unsealed, plastic dust cover.
T9AS: Immersion cleanable, sealed plastic case (2 & 3).
T9AV: Vented, flux-tight, plastic cover.
Weight: Q.C. version: 1.2 oz. (33g) approx. (mounting code 2 & 5).
Sealed Model T9AS: 0.9 oz. (26g) approx. (mounting code 1).
Notes
(1) Operating ambient temperature must consider “Must Operate Voltage
Change Over Temperature,” Contact Temperature Rise, Coil Temperature
Rise (If coil is not allowed to cool) and Maximum Coil Temperature.
Specification ambient considers 20A load with coil cooled to ambient.
(2) Sealed relay terminals should not be bent.
(3) Remove knock-off nib after cleaning process for optimum life of sealed
relays.
(4) Maximum soldering temperature is 500°F for 4 seconds.
(5) Class F coils are UL systems approved for maximum coil temperature of
140°C, by change of resistance method.
(6) See application note 13C265 for proper relay mounting, termination,
cleaning and PC board conductor width. Coil rise test performed with 30A
PC board to maintain 20°C maximum rise @ 30A.
Ordering Information
Typical Part Number B T9A S
5
D
2
2 -12
1. Basic Series:
T9A = Low cost, printed circuit board/panel power relay.
2. Enclosure:
P = Unsealed, plastic dust cover (mounting code 5).
S = Immersion cleanable, knock off nib, sealed plastic case (mounting codes 1 & 2).
V = Vented, flux-tight (mounting code 1).
3. Contact Arrangement:
1 = 1 Form A (SPST-NO).
5 = 1 Form C (SPDT).
4. Coil Input:
D = DC voltage (1 Watt)
L = DC voltage (900mW)
5. Mounting & Termination:
1 = Printed circuit board mounting; PC terminals for coil & contacts (a).
2 = Printed circuit board mounting; PC terminals for coil & contacts, and .250" (6.35mm) quick connects for contacts (b).
5 = Flanged mounting; .187" (4.75mm) quick connects for coil and .250" (6.35mm) quick connects for contacts (c).
6. Contact Material:
2 = Silver-cadmium oxide.
7. Coil Voltage:
5 = 5VDC
6 = 6VDC
9 = 9VDC
12 = 12VDC
15 = 15VDC
18 = 18VDC
20 = 20VDC
22 = 22VDC
24 = 24VDC
36 = 36VDC
48 = 48VDC
110 = 110VDC
a) Only available with enclosure code “S” & “V”. b) Only available with enclosure code “S”.
c) Only available with enclosure code “P”.
Stock Items – The following items are normally maintained in stock for immediate delivery.
T9AP1D52-12
T9AP1D52-24
T9AP1D52-48
T9AP5D52-12
T9AP5D52-24
T9AP5D52-48
T9AS1D12-110
T9AS1D12-12
T9AS1D12-18
T9AS1D12-24
T9AS1D12-48
T9AS1D12-5
T9AS1D22-110
T9AS1D22-12
T9AS1D22-24
T9AS1D22-48
T9AS1D22-5
T9AS1L12-12
T9AS1L12-24
T9AS5D12-110
T9AS5D12-12
T9AS5D12-18
T9AS5D12-24
T9AS5D12-48
T9AS5D12-5
T9AS5D22-110
T9AS5D22-12
T9AS5D22-24
T9AS5D22-48
T9AS5D22-5
T9AS5L12-12
T9AS5L12-24
61