English
Language : 

T9AS1D12-12 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – Low Cost 30 Amp PC Board or Panel Mount Relay
T9A series
Low Cost
30 Amp PC Board or
Panel Mount Relay
File E22575
File LR15734
Features
• Up to 30 amp switching in SPST and 20 amp in SPDT arrangements.
• Immersion cleanable(6), plastic sealed case available.
• Meets UL 873 and UL 508 spacing – 1/8" through air, 1/4" over surface.
• Load connections made via 1/4" Q. C. terminals and safety wells accept
insulated female Q. C. terminals (mounting codes 2 & 5).
• UL Class F insulation system standard.
• Well suited for various industrial, commercial and residential applications.
Contact Ratings @ 25°C with relay properly vented.
Remove vent nib after soldering and cleaning.
Arrangements: 1 Form A (SPST-NO), and 1 Form C (SPDT).
Material: Silver-cadmium oxide.
Mechanical Life: 10 million operations, typical.
Minimum Contact Load: 1A @ 5VDC or 12VAC.
Initial Contact Resistance: 75 milliohms, max., @ min. rated current (switched).
Typical Electrical Load & Life - 1 Watt Coil
Contact
Arrangement
Contact Load
Type of Load
1
30A @ 240VAC
UL General Purpose
25A @ 240VAC
Resistive Heater
5
20A/10A @ 240VAC UL General Purpose
20A/10A @ 240VAC
UL Resistive
20A/10A @ 28VDC
Resistive
Operations
100,000
100,000
100,000
100,000
100,000
Typical Electrical Load & Life - 900mW Coil
Contact
Arrangement
Contact Load
Type of Load
1
120VAC
50 LRA/16 FLA
120VAC
30 LRA/11 FLA
Operations
100,000
200,000
UL 508/873 & CSA Contact Ratings - 1 Watt Coil
Voltage
Load Type
N.O. Contact
277VAC
Tungsten *
5.4A
277VAC
Ballast
10A
240VAC
Motor
2 HP
240VAC
Resistive *
30A
240VAC
General Purpose†
30A
240VAC
LRA/FLA **††
80A/30A
240VAC
Pilot Duty *
470VA
125VAC
Motor
1 HP
120VAC
LRA/FLA
98A/22A
120VAC
Tungsten *
8.3A
120VAC
Pilot Duty
470VA
28VDC
Resistive
20A
* Rated 6,000 operations.
** Higher UL & CSA ratings available.
† For Form C application, derate current to 20A (N.O.), 10A (N.C.).
†† For Form C application, derate current to 67%.
N.C. Contact
–
3A
1/2 HP
20A
15A
30A/12A
275VA
1/4 HP
–
–
–
10A
Note: Consult factory for other 900mW version contact ratings.
60
Initial Dielectric Strength
Between Open Contacts: 1,500V rms.
Between Contacts and Coil: 2,500V rms.
6 kV surge using 1.2µs/50µs Impulse Wave or
.5µs – 100kHz Ring Wave
Initial Insulation Resistance
Between Mutually Insulated Elements: 109 ohms, min., @ 500VDC,
25°C and 50% R.H.
Coil Data @ 25°C
Voltage: 5 to 110VDC.
Nominal Coil Power: 1.0W, (approx.) and 900mW (approx.) versions.
Maximum Coil Power: 2.8 Watt.
Maximum Coil Temperature(5): Class F: 140°C.
Duty Cycle: Continuous.
Coil Data - 1 Watt
Nominal DC Resistance Nominal Nominal
Voltage ± 10% (Ohms) Current (mA) Voltage
5
25
6
36
9
81
12
144
15
225
200
18
167
22
111
24
83
48
67
110
DC Resistance Nominal
± 10% (Ohms) Current (mA)
324
56
484
45
576
42
2,304
21
12,100
9
Coil Data - 900mW
Nominal DC Resistance Nominal Nominal
Voltage ± 10% (Ohms) Current (mA) Voltage
5
27
6
40
9
97
12
155
15
256
18
380
20
450
185
22
150
24
93
28
77
36
59
48
47
110
44
DC Resistance Nominal
± 10% (Ohms) Current (mA)
545
40
660
36
890
31
1,450
25
2,560
19
13,450
8
Operate Data @ 25°C
Must Operate Voltage: 75% of nominal voltage or less.
Must Release Voltage: 10% of nominal voltage or more.
Operate Time (Including Bounce)§: 15 ms, max.
Release Time (Including Bounce)§: 15 ms, max.
§ At or From Nominal Coil Voltage